66

ISBN: 978-91-88898-64-7

Investigation of density variations in molded wood tubes using gamma-ray CT

and correlation with load-bearing behavior

Jens U. Hartig†*, André Bieberle, Chris Engmann and Peer Haller

Technische Universität Dresden, Faculty of Civil Engineering, Institute of Steel and Timber Construction,

01062 Dresden, Germany, jens.hartig@tu-dresden.de

Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden,

Germany, a.bieberle@hzdr.de

It is well known that mechanical properties of wood correlate with the density [1]. Since wood is a naturally grown material, variations in the density distribution still exist in timber elements leading to a non-uniform distribution of mechanical properties. To investigate the density distribution in timber elements at the meter scale non-destructively, the gamma-ray computed tomography (CT) scanner, firstly introduced in 2007 by Hampel et al [2], has been applied. The CT scanner offers a spatial resolution of about 1-2 mm. Nevertheless, small single structures like cracks or branches can be revealed up to a size of several micrometers.

As object of interest, a molded wooden tube (MWT) [2] with a length of 3 m and a diameter of 0.3 m made of beech (Fagus sylvatica) is used. The MWT is produced in a thermo-hydro-mechanical process incorporating densification and recovery of wood transverse to the grain [3]. Thus, besides naturally grown density variations also variations due to the production process of the MWT occur. Figure 1 (left) shows the density distribution in the MWT, measured plane-wisely along the MWT in discrete length distances of 50 mm.

Figure 1: Experimental results. (left): density distribution determined by CT in the MWT (not to scale), (right) axial strain distribution in the MWT at an axial loading of 900 kN

In order to verify the assumption that the mechanical properties correlate with the density, an axial compression test is performed with the MWT previously scanned with CT. The spatial deformations on the surface of the MWT were measured by photogrammetry and digital image correlation (DIC) is applied to determine the strain distribution, see Figure 1 (right).

The density and geometry data gathered by CT is also used to create a finite element (FE) model. Based on the density data, the elastic properties of the respective elements are defined. The axial compression test is simulated and the results in terms of the strain distributions are compared to the experimental data determined by DIC.

The results of the investigations showed that computed tomography is highly suitable for the non-destructive determination of the density distribution in structural elements of timber. Thus, besides for research purposes CT scanning might be used also in the future for industrial grading of timber elements.

References

[1] F.F.P. Kollmann, W.A. Côté, Jr.: Principles of Wood Science and Technology – I. Solid Wood. Springer-Verlag, 1968.

[2] U. Hampel, A. Bieberle, D. Hoppe, J. Kronenberg, E. Schleicher: High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications. Review of Scientific Instruments, 78 (2007), 103704. [3] J. U. Hartig, J. Wehsener, P. Haller: Experimental and theoretical investigations on moulded wooden tubes made of

beech (Fagus sylvatica L.). Construction and Building Materials, 126 (2016), 527-536.

[4] A. Kutnar, D. Sandberg, P. Haller: Compressed and moulded wood from processing to products – a review. Holzforschung, 69 (2015), 885-897.

Figure

Figure 1: Experimental results. (left): density distribution determined by CT in the MWT (not to scale), (right) axial strain  distribution in the MWT at an axial loading of 900 kN

References

Related documents

The speci fic objectives of this experimental study were 1) to develop the experimental setup and analytical procedure applied to separate compo- nents of the total de flection

This work is, to the author’s knowledge, pioneering in the in situ study with great reliability of the drying and conditioning of sawn timber with CT at the pixel level

Example of MC gradient measurements with the OD method and with the CT-scanner Summing up, the results of this study showed that it is possible to apply the CT-scanner technology

Book  of  Abstracts  of  the  4th  International  Conference  on  Process  Technologies   for  the  Forest  and  Biobased  Products  Industries

Nevertheless, these results show that DXA is applicable using such a range of medical CT scanning energies for in situ MC measurements, as well as for the determination of

PCA is defined as a multivariate projection method designed to extract and display the systematic variation in a data matrix, whereas PLS is a regression extension of PCA which is

To do so, a Scanning Electron Microscopy (SEM) and EBSD method was used to measure in-plane lattice rotations. The gradient of in-plane lattice rotation field gives the

The aim of this study is to investigate how deviations from nominal values of air gap length, and PM magnetization and size, affect the air gap magnetic flux density in a PMSG with