• No results found

Heat pumps and electric boilers including combination heaters

N/A
N/A
Protected

Academic year: 2021

Share "Heat pumps and electric boilers including combination heaters"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Nordsyn

– surveillance co-operation for green products

Heat pumps and electric

boilers including combination

heaters

Nordic Council of Ministers

This guide presents the technical documentation that you have to

pro-vide if the market surveillance authorities ask for it. There are however

other information requirements and requirements on web-information

that you always need to fulfil according to the regulations.

Technical documentation for heat pumps and electric boilers

Demands

How to comply

Content of Technical Documentation to provide to market surveillance authorities

Heat pumps and electric boilers are covered by ecodesign requirements according to Regulation (EU) No 813/2013 and energy labelling requirements according to Regulation (EU) No 811/2013.

The requirements apply to heat pumps and electric boilers as described in Article 1 and 2 of the above mentioned Regulations. The documentation shall be produced before the product is placed on the market.

The technical documentation shall be sufficient to enable assessment of the conformity of the product with the requirements. In this respect it is important that test reports are included in the technical documentation.

Name and address of supplier General description

List of applied standards

Identification and signature of the person empowered to bind the supplier

Calculations and precautions

Apply to both ecodesign and energy labelling

Technical parameters

Apply only to energy labelling

Company name and complete address.

Description of the model so that it is easily identified (model name and number, size etc.). Applied measurement standards (harmonised standards and/or other standards). Name and signature of the person responsible for the product.

Models where the data is obtained from another product model

For heat pump space heaters and heat pump combination heaters, where the information relating to a specific model with combined indoor and outdoor units is based on calculation or extrapolation from other combinations, state the details of such calculations or extrapola- tions, including details of the mathematical model for calculations and measurements.

Specific precautions

State any specific precautions that should be taken when heater is assembled, installed or maintained.

For electric boilers and combination heaters

Technical parameters set out in Regulation Annex V Table 7.

For heat pump space heaters, and heat pump combination heaters

Technical parameters set out in Regulation Annex V Table 8.

Please be aware that Table 7 and 8 in the energy labelling Regulation are not identical to Table 1 and 2 in the ecodesign Regulation. fa ct s ab ou t t he n ordi c co-op era tio n

THE NORDIC REGION

– leading in green growth

(2)

Nordic Council of Ministers Store Strandstræde 18 DK-1255 Copenhagen K Phone +45 33 96 02 00 Fax +45 33 96 02 02 www.norden.org

nordsyn september 2015

COMMISSION DELEGATED REGULATION (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device.

Technical documentation for heat pumps and electric boilers

Demands

How to comply

Technical parameters and product information

Apply only to ecodesign

For electric boilers and combination heaters

Technical parameters set out in Regulation Annex II Table 1.

For heat pump space heaters, and heat pump combination heaters

Technical parameters set out in Regulation Annex II Table 2

Production information

For heat generators designed for heaters, and heater housings, state their characteristics, requirements for assembly so it complies with ecodesign requirement, and where ap propriate the list of combinations recommended by the supplier.

Information relevant for disassembly, recycling and/or disposal at end-of-life. This guide presents the contents of the Regulations

and is addressed to manufacturers, importers and others interested. The guide is not a substitution for the Regulations, and in any case of doubt, the Regulations are applicable. This guide is not legally binding as a binding interpretation can only be made by the EU court.

2015:1101

COMMISSION REGULATION (EU) No 813/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters.

References

Related documents

Swedenergy would like to underline the need of technology neutral methods for calculating the amount of renewable energy used for cooling and district cooling and to achieve an

Industrial Emissions Directive, supplemented by horizontal legislation (e.g., Framework Directives on Waste and Water, Emissions Trading System, etc) and guidance on operating

Re-examination of the actual 2 ♀♀ (ZML) revealed that they are Andrena labialis (det.. Andrena jacobi Perkins: Paxton & al. -Species synonymy- Schwarz & al. scotica while

The plan area is also near an industrial area and a sewage treatment plant, which can cause noise and smell disturbance” (Municipality 1. Plan Description

Show how mili- tary men are done and un- done during an intense pepper spray exercise Key ana- lytical concepts Gender rela- tions, change, gender bounda- ries Boundary work,

This paper proposed a reconstruction scheme for the recov- ery of a uniformly sampled sequence from the output of a TI-ADC with static time-skew errors and missing samples.. In order

Abbey Pain Scale var det instrument, som nästan alla sjuksköterskor använde sig av för smärtbedömning hos demenssjuka och palliativa patienter även om inte alla respondenterna