• No results found

Standby and off mode and networked standby : Electric power consumption of electrical and electronic household  and office equipment

N/A
N/A
Protected

Academic year: 2021

Share "Standby and off mode and networked standby : Electric power consumption of electrical and electronic household  and office equipment"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Nordsyn

– surveillance co-operation for green products

Standby and off mode and

networked standby

Nordic Council of Ministers

This guide presents the technical documentation that you have to

pro-vide if the market surveillance authorities ask for it. There is however

other information requirements and requirements on web-information

that you always need to fulfil according to the regulations.

Electric power consumption of electrical and electronic household

and office equipment

Technical documentation for standby and off mode and networked standby, electric power

consumption of electrical and electronic household and office equipment

Demands

How to comply

Content of Technical Documentation to provide to market surveillance authorities

Electrical and electronic appliances are covered by standby ecodesign requirements according to Regulation (EC) No 1275/2008 and Amendment (EU) No 801/2013.

The requirements apply to electrical and electronic household and office equipment as described in Article 1 and 2. The documentation shall be produced before the product is placed on the market.

The technical documentation shall be sufficient to enable assessment of the conformity of the product with the requirements. In this respect it is important that test reports are included in the technical documentation.

Name and address of supplier General description

List of applied standards

Identification and signature of the person empowered to bind the supplier

Standby- and off-modes

For networked equipment

Company name and complete address.

Description of the model so that it is easily identified (model name and number, size etc.). Applied measurement standards (harmonised standards and/or other standards). Name and signature of the person responsible for the product.

For each standby and/or off mode

• The power consumption data in Watts. • The measurement method used.

• Description of how the equipment mode was selected or programmed. • The sequence of events to reach the mode where the equipment automatically

changes modes.

• Any notes regarding the operation of the equipment, e.g. information on how the user switches the equipment into a condition having networked standby. • The default time after which the power management function, or similar function,

has switched the equipment into the applicable low power mode or condition. • Number and types of network ports, and the locations of network ports • (except wireless network ports) on the equipment

• Declaration if the same physical network port accommodates two of more types of network ports

• State whether all network ports are deactivated before delivery • State whether equipment is a HiNA equipment or equipment with HiNA

functionality Power consumption shall comply with

the requirement described in regula- tion Annex II point 1 and point 2. Round to the second decimal place.

If no information is provided, the equipment is considered not to be networked equipment unless it provides functionalities of a router, network switch, wireless network access point (not being a terminal), hub, modem, VoIP telephone, video phone.

If no information provided, it is considered not the case

fa ct s ab ou t t he n ordi c co-op era tio n

THE NORDIC REGION

– leading in green growth

(2)

Nordic Council of Ministers Store Strandstræde 18 DK-1255 Copenhagen K Phone +45 33 96 02 00 Fax +45 33 96 02 02 www.norden.org

nordsyn september 2015

COMMISSION REGULATION (EC) No 1275/2008 of 17 December 2008 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for standby and off mode electric power consumption of electrical and electronic household and office equipment.

Technical documentation for standby and off mode and networked standby, electric power

consumption of electrical and electronic household and office equipment

Demands

How to comply

For each type of network port

Test conditions

Characteristics of equipment

• Default time after which the power management or a similar function switches the equipment into a condition providing networked standby.

• State the trigger used to reactivate the equipment. • Maximum performance specifications.

• Maximum power consumption of the equipment in a condition providing networked standby (given the equipment is switched into this condition by power management or similar function), if this port is used to reactive the equipment.

• State the communication protocol used by the equipment. • Ambient temperature

• Test voltage in V and frequency in Hz

• Total harmonic distortion (THD) of the electricity supply system

• Information and documentation on the instrumentation, set-up and circuits used

• State the availability of off mode and/or standby mode and/or power

management under ecodesign requirement 1(c), 2(c), 2(d), 3(b) of Regulation Annex II, if applicable, including the time taken to automatically reach the mode.

• Technical justification shall be provided if the requirements on off-mode ,

standby mode and power management under point 1(c), 2(c), 2(d), 3(b) of the Regulation Annex II are inappropriate for intended use of the equipment.

This guide presents the contents of the Regulations and is addressed to manufacturers, importers and others interested. The guide is not a substitution for the Regulations, and in any case of doubt, the Regulations are applicable. This guide is not legally binding as a binding interpretation can only be made by the EU court.

2015:1101

COMMISSION REGULATION (EU)

No 801/2013 of 22 August 2013 amending Regulation (EC) No 1275/2008 with regard to ecodesign requirements for standby, off mode electric power consumption of electrical and electronic household and office equipment, and amending Regulation (EC) No 642/2009 with regard to ecodesign requirements for televisions.

The need to maintain one or more network connections or to wait for a remotely initiated trigger is not considered a technical justification for exemption from the power management requirements set out in 2(d) in the case of equipment that is not defined as networked equipment by the manufacturer.

References

Related documents

In addition, a switched bond graph implicitly repre- sents the mode transitions and the conditions for switching between modes.. To derive a mode-specic bond graph for a partic-

1) Annto logistics should build a tighter connection with Midea manufacturing factories by using ALIS2.0, which means ALIS2.0 should be implanted into Midea manufacturing

I och med detta skall endast de två universalinredena användas för larmbågar till brandbilar, detta kommer att medföra att komponent-lagret kommer att minska avsevärt..

Figure 4.4: The fitting linear piecewise function of the voltage from 3.9 V to 3.7 V for NB-IoT end device with the data of sample No.. Based on the voltage data we collected, as

Författarna till denna uppsats är av uppfattningen att inga särskilda skäl finns för Bokakademin att genomföra en detaljerad segmentering, detta på grund av

I detta projekt ska en fallstudie genomföras för att undersöka hur en interaktiv prototyp kan utformas för att underlätta vid redovisning av kvitton och underlag för

GK1 bör endast användas då små och enkla bärverk dimensioneras. Det skall kunna visas att de grundläggande kraven uppfylls genom erfarenhet och kvalitativa geotekniska

Qian, C., Zhang, Y., Liu, Y., Wang, Z., (2019), A cloud service platform integrating additive and subtractive manufacturing with high resource efficiency, Journal of