• No results found

APPENDIX A. MARKER SITES AND DATAFILE COLUMNS

N/A
N/A
Protected

Academic year: 2021

Share "APPENDIX A. MARKER SITES AND DATAFILE COLUMNS"

Copied!
3
0
0

Loading.... (view fulltext now)

Full text

(1)

APPENDIX A. MARKER SITES AND DATAFILE COLUMNS A-1

MITRAL VALVE MECHANICS by Neil B. Ingels, Jr. and Matts Karlsson

APPENDIX A. MARKER SITES AND DATAFILE COLUMNS

Datafiles (provided in this Appendix) associated with the six heart (H1-H6) study are:

HEART CONTROL STUDY

FILE1 FILE2 H1 NAC03R04.1EC NAC03R04.1IC H2 NAM14R01.1EC NAM14R01.1IC H3 NAM18R03.1EC NAM18R03.1IC H4 NSA12R01.1EC NSA12R01.1IC H5 NAC09R03.1EC NAC09R03.1IC H6 NAS07R03.1EC NAS07R03.1IC o Each datafile has (if the parameter was successfully recorded)

Electrocardiogram (mV) in Column 4

Left Ventricular Pressure (mmHg) in Column 5 Left Atrial Pressure (mmHg) in Column 6 Aortic Pressure (mmHg) in Column 7

• In addition, *.1EC datafiles have (See Figure A.1)

o Marker#1 x, y, z lab coordinates (cm) in Columns 11, 12, 13 o Marker#2 x, y, z lab coordinates (cm) in Columns 14, 15, 16 o …

o Marker#13 x, y, z lab coordinates (cm) in Columns 47, 48, 49 o Marker#14 is not used, placeholders in Columns 50, 51, 52 o Marker#15 x, y, z lab coordinates (cm) in Columns 53, 54, 55 o …

o Marker#31 x, y, z lab coordinates (cm) in Columns 101, 102, 103 o Marker#32 is not used, placeholders in Columns 104, 105, 106 o Marker#33 x, y, z lab coordinates (cm) in Columns 107, 108, 109 • In addition, *.1IC datafiles have (as Markers#34, 35, 36 were not used)

(See Figure A.1)

o Marker#37 x, y, z lab coordinates (cm) in Columns 20, 21, 22 o Marker#38 x, y, z lab coordinates (cm) in Columns 23, 24, 25 o …

o Marker#53 x, y, z lab coordinates (cm) in Columns 68, 69, 70 (#53 is the last marker)

Each datafile row is a single sample time, with sampling occurring 60 times/sec (i.e. every 16.67msec). Row numbers correspond in 1EC and 1IC datafiles.  Marker numbers were assigned so as to retain backward compatibility with

(2)

APPENDIX A. MARKER SITES AND DATAFILE COLUMNS A-2

MITRAL VALVE MECHANICS by Neil B. Ingels, Jr. and Matts Karlsson

MARKER LOCATIONS: LEFT VENTRICULAR, MITRAL ANNULAR, AND

PAPILLARY MUSCLES

LEFT VENTRICULAR (LV) MARKERS

o LV Apex (Marker#1)

o LV Anterior Subepicardium, apical plane (Marker#2), equatorial plane (Marker#3), basal plane (Marker#4), inserted before the pump run

o LV Septal Subendocardium, apical plane (Marker#5), equatorial plane (Marker#6), basal plane (Marker#7), inserted during the pump run

o LV Posterior Subepicardium, apical plane (Marker#8), equatorial plane (Marker#9), basal plane (Marker#10) , inserted before the pump run

o LV Lateral Subepicardium, apical plane (Marker#11), equatorial plane (Marker#12), basal plane (Marker#13) , inserted before the pump run

(3)

APPENDIX A. MARKER SITES AND DATAFILE COLUMNS A-3

MITRAL VALVE MECHANICS by Neil B. Ingels, Jr. and Matts Karlsson

MITRAL ANNULUS (ALL MARKERS PLACED AT DIRECTLY OBSERVED

LEAFLET “HINGE” LOCATIONS DURING THE PUMP RUN)

o Trigone Region

Left Fibrous Trigone(LFT) (Marker #29) “Saddlehorn” (SH) (Marker#22)

Right Fibrous Trigone (RFT) (Marker #24) LFT to SH (Markers#15,30)

SH to RFT (Markers#23,21) o Contractile Annulus

Anterior Commissure (AC) (Marker#16) Lateral Annulus (Marker#18)

Posterior Commissure (PC) (Marker#20 AC to Lateral Annulus (Markers#28,17,27) Lateral Annulus to PC (Markers#26,19,25) • PAPILLARY MUSCLES (INSERTED DURING THE PUMP RUN)

o Anterior Papillary Muscle Tip (Marker#31) o Posterior Papillary Muscle Tip (Marker#33)

MARKER LOCATIONS: LEAFLETS

• ANTERIOR LEAFLET

o Trigone Region (See Figure 01) is the Anterior Leaflet Hinge Region o Leaflet Edge (markers sewn to atrial side of leaflet)

Central Edge (Marker#38)

LFT to Central Edge (Markers#42,43,44) Central Edge to RFT (Markers#45,46,47)

Central Meridian from Central Edge to SH (Markers#39,40,41) Left Belly (Markers#48,50,51)

Right Belly (Markers#49,52,53) • POSTERIOR LEAFLET

o Only one marker (Marker#37) sewn to the central meridian edge of the central scallop for timing of valve opening and closing

References

Related documents

As with the Rosenfeld digitization, it is possible to show that a continuous digitization satisfies the chord property for a certain metric and, conversely, under some natural

På samma sätt är vegetationssäsongens början, slut och längd samt maximalt tjäldjup och första tjälfria dag återgivna i Figur 16—20.1 varje figur återges temperatursummor

seminariet/webbinariet – se nedan!). Under utställningen fungerade arkivskåpet som en skiss till detta alfabetiskt uppbyggd essäverk; vi fyllde fem lådor med ett innehåll som angav

That the infinitive marker of the main verb is being lost after kommer is not a novel observation. 4: 243-244) that komma normally takes an infinitive phrase which

Markers #15, 22, and 21 are trigonal, Marker #16 is at the anterior commissure, Marker #20 at the posterior commissure, Markers #17, 18, and 19 are on the contractile portion of the

Lagrange's stability theorem If in a certain rest position x 0 , where G 0 (x 0 ) = 0 , a conservative mechanical system has minimum potential en- ergy, then this position

The sprayed sheets were dried unrestrained or fully restrained to study how in-plane moisture variations could affect paper properties and out-of-plane deformation..

In this paper, we will present an analytic model of the Euclidean plane in first section, linear transformations of the Euclidean plane in second sec- tion, isometries in third