AMPLIFIER BAA 2000-E

vib

HAUPTSCHALTER MAIN SWITCH

ON

ON OFF OKPA

UBIB

IS _IS+

ID TMP

LCDSYSTEM CAL SIGNAL LEVEL

GAIN 2GAIN 1

Reset Reset

SE OKVC CC INTENSCURRENTLIMITERVOLTAGECLIPPINGOUTPUTOFFSET

STATUS

DESCRIPTION

TIRA shakers reproduce vibration environment under laboratory conditions for testing the dyna- mic strength and the reliability in all fields of vib- ration testing.

TIRA shakers are designed for long-time ope- ration. They are distinguished by their high trans- verse vibration strength and high axial stiffness.

The electrodynamic shaker is pivotally mounted in a rugged frame and enables the excitation in vertical and horizontal direction.

An automatic, pneumatic operated load compensation allows the realization of the no- minal vibration displacement, even with heavy test loads. The frame is equipped with air isolation mounts according to standard. The transmission of vibrations onto the place of erection is reduced to a minimum; an additional foundation (seismic mass) is not required in most cases. A maintenance-free blower guarantees the cooling of the shaker. The cooling air is sucked in via a filtersystem.

TIRA shakers, amplifiers and vibration control sys- tems represent a complete test system offering the users the possibility to establish proof of the quality of their products according to national and international standards(such as DIN, ISO, BS, MIL, IEC, ASTM).

TV 50350-120

Vibration Test System

AMPLIFIER BAA 2000-E AMPLIFIER A 1 01 1 004

KVA ratings 4200 VA

Frequency range DC-4 kHz

Voltage, max. 105 V

Current, max. 40 A

Load resistance 2.6 Ohm

Input voltage 2.5/5/10 V

Distortion <0.5 %

Signal to noise ratio > 90 dB Field voltage, max. 100/180 V Field current, max. 6 A

Weight 225 kg (496.0 lb)

Size (WxHxD) 600 x 1800 x 800 mm

(23.6 x 70.9 x 31.5 in)

(2)

TECHNICAL SPECIFICATION VIBRATION GENERATOR S 50350-120

PERFORMANCE DIAGRAM

DIMENSIONS (mm)

Cooling (m³/h|ft³/min) 200 118 Interlocks Temperature, overtravel, airflow, overcurrent, compressed air Stray magnetic field (mT) without/with degauss kit <8.5/<0.5 <8.5/<0.5 Rated peak force (N|lbf) Sine/Random/Shock 2700/2000/4000 607/450/900 Frequency range (Hz) DC-4000 DC-4000 Max. rated travel (mm|inch) Pk-Pk 25.4 1.0

Max. velocity (m/sec|inch/sec) Sine/Random/Shock 1.5/1.5/2.5 59/59/98 Max. acceleration (g) Sine/Random/Shock 110/81/163 110/81/163

Max. power consumption at 400 V (kVA) 5.5 5.5 Nominal impedance (Ohm) 2 2 Suspension stiffness (N/mm|lbf/inch) 22 125.6

Effective moving mass (kg|lb) 2.5 5.5 Main resonance frequency (Hz) >4000 >4000 Weight with trunnion (kg|lb) 280 617.3 Armature ( /mm|ø/inch) 120 4.72 Max. weight tested (kg|lb) 25 55.1

S 50350-120 (Example drawing)

Depth 411 mm

Blower SB 0310

378

125 290 325 384 333

Ein In

Aus Out

ø120 ø80

7x M8

60°

Armature 120

GmbH

96528 Schalkau Eisfelder Str. 23-25 Germany Tel.: +49 36766 280-0 Fax: +49 36766 280-99 Internet: www.tira-gmbh.de e-mail: st@tira-gmbh.de

Subject to modifications

System Performance TV 50350-120

1 10 100 1000

1 10 100 1000 10000

Frequency [Hz]

Acceleration[g] 1,5 m/s

m=0 Kg 110 g

m=5 Kg 36,7 g

m=13 Kg 17,8 g

m=25 Kg 10,0 g

25,4 mm

Force: 2700 N max. Acceleration: 110 g max. Velocity: 1,5 m/s max. Displacement: 25,4 mm

References

Related documents

För att då öka verklighetsgraden på testerna borde Euro Ncap testa hur både fordonen och systemet beter sig när friktionen i väglaget är lägre och när vädret inte är

This work focuses on the development of this test fluid which will be composed of calcium soap, or calcium methyl nonanediate in its full name, as soft particles,

In this work, unbalanced magnetron of type II was used during the MSE of GaN, because the magnetic field of this type of magnetron not only traps electrons and enhance

(19861.0 Paraqletric and non-parametric tests for bioequivalence trials. of Statistics, University of Goteborg. Stochastic deviation from elliptical shape. Almqvist

In this thesis we have outlined the current challenges in designing test cases for system tests executed by a test bot and the issues that can occur when using these tests on a

Based on our results gamification does increase the motivation of developers and it did improve the quality of unit tests in terms of number of bugs found, but not in terms of

Static validation of the MT process suggested that MT has ability to resolve the weaknesses of both test approaches to some extent such as issues related to test oracles,

The communication between the controller and the light bulbs during EZ-mode commissioning reveals a major security flaw in that the network key necessary for devices to join the