Low-dose computed tomography of the abdomen and lumbar

spine

av

Muhammed Alshamari

Akademisk avhandling

Avhandling för medicine doktorsexamen i Medicinsk vetenskap som kommer att försvaras offentligt

fredag den 08 april 2016 kl. 13.00, Bohmanssonsalen, Universitetssjukhuset Örebro

Opponent: Professor Seppo Koskinen

Institutionen för klinisk vetenskap, intervention och teknik, Karolinska institutet,

Stockholm, Sverige

Örebro universitet

Institutionen för medicinska vetenskaper 701 82 ÖREBRO

(2)

Abstract

Muhammed Alshamari (2016): Low-dose computed tomography of the abdo-men and lumbar spine. Örebro Studies in Medicine 137.

Radiography is a common radiologic investigation despite abundant evidence of its limited diagnostic value. On the other hand, computed tomography (CT) has a high diagnostic value and is widely considered to be among the most important advances in medicine. However, CT exposes patients to a higher radiation dose and it might therefore not be acceptable simply to replace radiography with CT, despite the powerful diagnostic value of this technique. At the expense of reduced CT image quality, which could be adjusted to the diagnostic needs, low-dose CT of abdomen and lumbar spine can be performed at similar dose to radi-ography. The aim of the current thesis project was to evaluate low-dose CT of the abdomen and lumbar spine and to compare it with radiog-raphy. The hypothesis was that CT would give better image quality and diagnostic information compared to radiography at similar dose levels. Firstly, the diagnostic accuracy of low-dose CT of the abdomen was evaluated. Results showed that low-dose CT of abdomen has a high sensitivity and specificity compared to radiography, i.e., it has higher diagnostic accuracy. Similar results were obtained from our systematic review. Secondly, in a phantom study, an ovine phantom was scanned at various CT settings. The image quality was evaluated to obtain a proto-col for the optimal settings for low-dose CT of lumbar spine at 1 mSv. This new protocol was then used in a clinical study to assess the image quality of low-dose CT of the lumbar spine and compare it to radiog-raphy. Results showed that low-dose CT has significantly better image quality than radiography. Finally, the impact of Iterative reconstruction (IR) on image quality of lumbar spine CT was tested. Iterative recon-struction is a recent CT technique aimed to reduce radiation dose and/or improve image quality. The results showed that the use of medium strength IR levels in the reconstruction of CT image improves image quality compared to filtered back projection. In conclusion, low-dose CT of the abdomen and lumbar spine, at about 1 mSv, has better image quality and gives diagnostic information compared to radiography at similar dose levels and it could therefore replace radiography.

Keywords: Tomography, X-Ray Computed; Radiography; Radiation

Dosage; Abdomen; Spine; Lumbosacral Region; Regression Analysis. Muhammed Alshamari, School of Medical Sciences, Örebro University, SE-701 82 Örebro, Sweden, muhammed.alshamari@gmail.com

References

Related documents

In our institution we developed a new grading system for the evaluation of screw placement, where the relationship of every individual screw to the corresponding pedicle,

 Effective dose estimations dedicated for diagnostic nuclear medicine based on the definitions in ICRP Publication 103 can be performed with the new anatomical mathematical

an image quality phantom using different radiation dose levels and iterative image optimisation levels (Paper I).. Philips IR and MBIR were futher investigated for abdominal CT

On top of that, modern CT scanners o↵er a high degree of configurability and sophis- tication where image quality can be manipulated using di↵erent parameters for image

Since the discovery of X-rays in 1896, radiography has been a common and well-known method in diagnostic imaging, especially in the imaging of the abdomen and lumbar spine,

Via a focus on the representations of the non-human world that become visible through the design, content, and rationality of the new installations in Swedish

The studies performed with the CT technique using low-dose protocols was the incentive to Study IV with the purpose to compare image quality of images obtained with

Keywords: Cone beam computed tomography, anatomic landmarks, dose-area product, image quality, implant planning, periapical diagnosis, radiation dosimetry. Swedish Dental