Gustafsson, M. (2018). Energy efficiency measures in the built environment - some aspects to consider in Sweden (PhD dissertation). Gävle University Press, Gävle. Available at http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-27986

Location

1

Error Correction

Page 40, Table 12 Row 4 to 6 should be row 7 to 9

New table below

Table 1. Summary of calculated PE numbers for all heating system combinations combined with a 25 kWp PV system or a 100 m2 ST system.

Heating source PEel factors PEel and PEDH

factors

1.6 2.5 1.85 and 0.95

District heating 59.0 61.9 57.1

District heating + ST system 53.1 55.9 51.5 District heating + PV system 57.1 58.9 54.9

Exhaust air heat pump 36.5 57.1 30.1

Exhaust air heat pump + ST system 30.7 48.0 25.6 Exhaust air heat pump + PV system 31.3 48.9 23.4 Ground source heat pump 26.0 40.6 42.2 Ground source heat pump + ST

system 22.2 34.6 35.5

Ground source heat pump + PV

system 20.2 31.6 36.2

1 Location = Page, paragraph, line, caption, figure, table, row, column, appendix

References

Related documents

Second, because normative goal-framing was expected to increase feelings of moral obligation and oughtness of pro-environmental behavior (Lindenberg & Steg, 2007, 2013;

According to previous studies, environments that is perceived as small-scale is generally preferred, while large-scale environments elicit negative emotions (Granström &

The thesis is based on three empirical studies in which particular attention is paid to detailing the impact of geographic factors on various daily travel activities (paper I);

The thesis is based on three empirical studies in which particular attention is paid to detailing the impact of geographic factors on various daily travel activities (paper

The audit consisted in a site visit, collection of interesting data, analysis of current energy performance of Fresco 2 store and further proposal of resource

The factors such as renewable sources, electrolyzer technology, fuel cells included in hydrogen production are optimized for this project in a cost-effective manner over the

The objective was to find out if there is a way to explain the temperature corrected energy use of the Swedish building stock by an equation consisting of energy

At the moment, to ensure reliable and high-quality electricity supply on the island as well as transmission of the total wind power production, the local grid company,