• No results found

Appendix C – Specific values at different receiver temperatures and solar irradiances

N/A
N/A
Protected

Academic year: 2021

Share "Appendix C – Specific values at different receiver temperatures and solar irradiances"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Appendix C – Specific values at different receiver temperatures and solar irradiances

i

Table C-1: All values, except the percentages, are presented in the unit W/m². The receiver setups are; a) aluminum plate with coating covering top of receiver, b) aluminum plate with coating covering both top and bottom of receiver and c) original receiver setup. Further details about the setups can be studied in section 5.3.1 of the report.

800 800 800 400 400 400 800 800 800 400 400 400 800 800 800 400 400 400 42 42 42 21 21 21 42 42 42 21 21 21 42 42 42 21 21 21 91 73 -20% 73 -20% 67 48 -28% 48 -28% 66 56 -15% 55 -17% 41 31 -25% 30 -28% 44 41 -9% 39 -12% 20 16 -22% 14 -29% 133 122 -8% 129 -3% 94 83 -12% 89 -4% 105 102 -3% 106 1% 66 62 -6% 66 0% 83 85 3% 86 5% 43 45 4% 46 8% 37 30 -21% 30 -21% 27 19 -29% 19 -29% 27 23 -16% 22 -17% 17 12 -26% 12 -28% 18 16 -9% 16 -12% 8 6 -22% 6 -29% 44 40 -8% 43 -3% 31 27 -12% 29 -5% 34 33 -3% 35 1% 21 20 -6% 21 0% 27 28 3% 28 5% 14 14 4% 15 8% 453 493 9% 485 7% 161 202 26% 193 20% 526 545 3% 541 3% 234 254 8% 250 7% 586 589 0% 589 0% 294 298 1% 298 1% 73 73 73 36 36 36 82 82 82 41 41 41 91 91 91 45 45 45 381 421 11% 412 8% 125 166 33% 157 26% 444 463 4% 459 3% 193 213 10% 209 8% 496 498 1% 498 1% 249 253 2% 253 1% 572 572 -0,1% 572 -0,1% 286 286 -0,1% 286 -0,1% 572 572 -0,1% 572 -0,1% 286 286 -0,1% 286 -0,1% 572 572 -0,1% 572 -0,1% 286 286 -0,1% 286 -0,1% 33 31 -5% 31 -4% 35 34 -4% 34 -4% 10 7 -23% 8 -18% 13 10 -17% 11 -13% -12 -14 22% -14 17% -9 -11 28% -11 22% 17 17 3% 17 3% 17 18 3% 18 3% 7 8 3% 8 4% 8 8 3% 8 4% -1 -1 -9% -1 -12% -1 0 -22% 0 -29% 43 28 -36% 36 -16% 45 29 -36% 37 -16% 16 10 -36% 14 -16% 18 12 -36% 15 -16% -3 -2 -35% -3 -13% -1 -1 -35% -1 -11% 27 3 -89% 3 -89% 28 3 -89% 3 -89% 13 1 -89% 1 -89% 13 1 -89% 1 -89% 2 0 -93% 0 -92% 3 0 -92% 0 -91% 453 493 9% 485 7% 161 202 26% 193 20% 526 545 3% 541 3% 234 254 8% 250 7% 586 589 0% 589 0% 294 298 1% 298 1% Receiver temperature 75°C 49°C 25°C

Coating AlO Solkote AlO Solkote AlO Solkote AlO Solkote AlO Solkote AlO Solkote

Setup c b a c b a c b a c b a c b a c b a Solar Irradiance Reflectional loss at glazing Convectional loss at glazing Convectional loss at backside of reflector sheet Radiational loss at glazing Radiational loss at backside of reflector sheet Total powerproduction Electric Thermal Receiver values Incoming radiation Convectional loss at PV side of receiver Convectional loss at top of receiver Radiational loss at PV side of receiver Radiational loss at top

of receiver

Total powerproduction

(2)

ii Table C-2: All values, except the percentages, are presented in the unit W/m². The receiver setups are; a) aluminum plate with coating covering top of receiver, b) aluminum plate with coating covering both top and bottom of receiver and c) original receiver setup. Further details about the setups can be studied in section 5.3.1 of the report.

800 800 800 800 800 800 800 800 800 42 42 42 42 42 42 42 42 42 91 70 -23% 70 -23% 66 53 -20% 52 -21% 44 38 -15% 36 -19% 133 119 -11% 125 -5% 105 98 -6% 102 -3% 83 81 -2% 83 0% 37 29 -24% 28 -24% 27 21 -20% 21 -21% 18 15 -15% 15 -19% 44 39 -11% 41 -6% 34 32 -7% 33 -3% 27 26 -2% 27 0% 453 502 11% 493 9% 526 554 5% 550 4% 586 598 2% 598 2% 73 73 73 82 82 82 91 91 91 381 429 13% 421 11% 444 472 6% 468 5% 496 507 2% 507 2% 572 581 2% 581 2% 572 581 2% 581 2% 572 581 2% 581 2% 33 32 -3% 32 -2% 10 8 -15% 9 -10% -12 -14 15% -13 11% 17 17 3% 17 3% 7 8 4% 8 5% -1 -1 -15% -1 -19% 43 28 -36% 36 -16% 16 11 -35% 14 -16% -3 -2 -39% -2 -18% 27 3 -88% 3 -88% 13 1 -89% 1 -89% 2 0 -91% 0 -90% 453 502 11% 493 9% 526 554 5% 550 4% 586 598 2% 598 2% Receiver temperature 75°C 49°C 25°C

Coating AlO SolMax AlO SolMax AlO SolMax

Setup c b a c b a c b a Solar Irradiance Reflectional loss at glazing Convectional loss at glazing Convectional loss at backside of reflector sheet Radiational loss at glazing Radiational loss at backside of reflector sheet Total powerproduction Electric Thermal Receiver values Incoming radiation Convectional loss at PV side of receiver Convectional loss at top of receiver Radiational loss at PV side of receiver Radiational loss at top

of receiver Total powerproduction

References

Related documents

Simulation results show that a large performance gain can be achieved for large packets, while for smaller packets the performance gain become smaller, because errors are more likely

From relevant links, in particular the ones found under the tabs “About Novia”, “Degree Students” and “Exchange Students” you will find information about Campus

När uppspelningskällan är CD, använd detta för att hoppa till föregående eller nästa spår.. När uppspelningskällan är DAB/FM, använd för att

Enheten innehåller dubbla interna antenner för förbättrad räckvidd inomhus och kommunicerar mottagen information vidare via Ethernet eller GPRS till överliggande system!. Produkten

Impact study of operating temperatures and cell layout under different concentration factors in a CPC-PV solar collector in combination with a vertical glass receiver composed

The other respondent that said that he did not send videos due to them containing different brands, later gave us an example where he sent a Pepsi commercial video with

C) J. "Experimental and numerical performance analyses of a Dish-Stirling cavity receiver: Geom- etry and operating temperature studies", Solar energy, Vol. Garrido

Parabolic trough power plants consist mainly out of four parts: The solar collector field, the auxiliary burner, the thermal storage and the power block (see figure 3.1).. The