• No results found

Quantitative detection of bacterial DNA in whole blood in bloodstream infection

N/A
N/A
Protected

Academic year: 2021

Share "Quantitative detection of bacterial DNA in whole blood in bloodstream infection"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Quantitative detection of bacterial DNA in whole blood in

bloodstream infection

av

Ingrid Ziegler

Akademisk avhandling

Avhandling för medicine doktorsexamen i Medicinsk vetenskap,

som kommer att försvaras offentligt fredagen den 5 oktober 2018 kl. 13.00, Hörsal C1, Campus Universitetssjukhuset Örebro

Opponent: Professor Magnus Rasmussen Lunds Universitet

Lund

Örebro universitet

Institutionen för Medicinska vetenskaper 701 82 ÖREBRO

(2)

Abstract

Ingrid Ziegler (2018): Quantitative detection of bacterial DNA in whole blood in bloodstream infection. Örebro Studies in Medical Science 183 This thesis aims to increase the knowledge on how quantitative PCR can be used in the diagnostics of bloodstream infections, with an emphasis on quantitative elements.

In Papers I and II, we evaluated quantitative data from two commer-cial PCR tests for pathogen detection directly in blood, Magicplex Sepsis (I) and SeptiFast (II), from patients with suspected sepsis. We found that high quantification cycle (Cq) values, indicating low DNA loads, were associated with findings of pathogens with doubtful clinical relevance, whereas low Cq values, indicating high DNA loads, were correlated with sepsis and septic shock, as well as with positive blood culture results.

In Paper III, we aimed to study the bacterial DNA load during Staphy-lococcus aureus bacteremia, in relation to different clinical factors. For this purpose, we developed a droplet digital PCR (ddPCR) for precise DNA quantification, targeting S. aureus specifically. We found that a high initial S. aureus DNA load was associated with laboratory markers for immune dysregulation as well as with sepsis, endocarditis, and mortality.

In Paper IV, we aimed to develop a tool for repeated DNA quantifica-tion during bloodstream infecquantifica-tion. For this purpose, we optimized a ddPCR, targeting the universal bacterial 16S rDNA, and performed a comparison with species-specific ddPCRs on spiked blood, and on clini-cal samples. The performance of the16S rDNA ddPCR was adequate, and we found that a high 16S rDNA load was associated with sepsis and mortality.

In conclusion, our results indicate that the pathogen DNA load in blood plays an important role in the clinical picture in BSI. In future research on molecular BSI diagnostics, studies on DNA loads and clear-ance should be included.

Keywords: bloodstream infection, bacteremia, sepsis, DNA load, quantita-tive PCR, droplet digital PCR, 16S rDNA

Ingrid Ziegler, School of Health and Medical Sciences, Örebro University, SE-701 82, Sweden, ingrid.ziegler@regionorebrolan.se

References

Related documents

For amplification of blaSHV, blaLEN and blaOKP in the 21 clinical isolates, new primers (table 1, sets 2-5) were designed that were universal for all three sequences.. The new

She accomplished the Specialist Degree in 2011, and is currently working as an Infectious Diseases Specialist at the Department of Infec- tious Diseases at Örebro

Analysis of Massive MIMO Base Station Transceivers Christopher Mollén. Linköping Studies in Science and Technology,

This forms a basis for comparison between different theoretical perspectives to explain households’ GHG emissions paper 1, allows us to examine if and how GHG intensive lifestyles

The main conclusions from this thesis were: i) DNA from dead bacteria can be detected by PCR years after cell death ex vivo and in vitro. ii) Cell-bound DNA is less prone to

In  connection  with  sampling,  transport,  registration  and  aliquoting  bio‐

Myndigheten för samhällsskydd och beredskap (MSB) har tagit del av utkast till lagrådsremiss avseende "En konsultationsordning i frågor som rör det samiska

17 Other findings where LightCycler FastStart DNA Master SYBR Green I kit (Roche Diagnostics) showed higher sensitivity than Mastermix 16S Basic Kit (Molzym) included higher