Gas Chromatography-Atmospheric Pressure Chemical Ionization-Tandem Mass Spectrometry Methods for the Determination of Environmental Contaminants

N/A
N/A
Protected

Academic year: 2021

Share "Gas Chromatography-Atmospheric Pressure Chemical Ionization-Tandem Mass Spectrometry Methods for the Determination of Environmental Contaminants"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Gas Chromatography-Atmospheric Pressure Chemical

Ionization-Tandem Mass Spectrometry Methods

for the Determination of Environmental Contaminants

av

Dawei Geng

Akademisk avhandling

Avhandling för filosofie doktorsexamen i kemi, som kommer att försvaras offentligt fredagen den 30 september 2016 kl. 10.15,

Hörsal M, Örebro universitet Örebro Opponent: Dr. Kees Olie

University of Amsterdam, The Netherlands

Örebro universitet

Institutionen för naturvetenskap och teknik 701 82 ÖREBRO

(2)

Abstract

Dawei Geng (2016): Gas Chromatography-Atmospheric Pressure Chemical Ionization-Tandem Mass Spectrometry Methods for the Determination of Environmental Contaminants. Örebro Studies in Chemistry 17.

The recent developments and improvements of instrumental methods for the analyses of the environmental contaminants, especially the persistent organic pollutants (POPs), have made it possible to detect and quantify these at very low concentrations in environmental and biotic matrices.

The main objective of this thesis is to demonstrate the capability of the atmospheric pressure chemical ionization technique (APCI), using gas chro-matography coupled to tandem mass spectrometry for the determination of a wide range of environmental contaminants, including the POPs regulated by Stockholm Convention, such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybromin-ated diphenyl ethers (PBDEs), but also the derivates of PBDEs and novel brominated flame retardants (NBFRs).

The APCI was operated in charge transfer condition, preferably produc-ing molecular ions. Multiple reaction monitorproduc-ing (MRM) experiments were optimized by adjusting cone voltage, collision energy and dwell time. Opti-mization of source parameters, such as gas flows and temperatures was also performed. Low concentration standards were analyzed, achieving a visible chromatographic peak for 2 fg 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) demonstrating the excellent sensitivity of the system. Adequate lin-earity and repeatability were observed for all the studied compounds. The performance of APCI methods was validated against the conventional meth-ods using gas chromatography coupled to high resolution mass spectrome-try for chlorinated compounds in a wide range of matrices including envi-ronmental, air, human and food matrices.

The GC-APCI-MS/MS method was successfully applied to a set of 75 human serum samples to study the circulating levels of POPs in epidemio-logic studies. Moreover the method was utilized to establish temporal trends of POPs in osprey eggs samples collected during the past five decades.

Keywords: PCDD/Fs, PCBs, OCPs, PBDEs, NBFRs, APCI, MS/MS,

HRMS, human serum, osprey egg.

Dawei Geng, School of Science and Technology, Örebro University, SE-701 82 Örebro, Sweden, dawei.geng@oru.se

References

Related documents

Electrospray Ionisation 4.1 General principle of electrospray 4.2 The role of ESI in analytical chemistry 4.3 Electrospray development history 4.4 ESI ionisation process 4.4.1

Key words: Mass spectrometry, electrospray ionization, drug discovery, noncovalent interaction, complexes, human serum albumin HSA, fatty acid binding protein FABP, ribonuclease,

The main objective of this thesis is to demonstrate the capability of a soft ionization technique, atmospheric pressure chemical ionization (APCI), using gas chromatography coupled

The main objective of this thesis is to demonstrate the capability of the atmospheric pressure chemical ionization technique (APCI), using gas chro- matography coupled to tandem

Therefore, in order to improve our understanding on MeHg chemical speciation, we developed a novel analytical method for direct determination of MeHg complexes

Separation of nineteen different endogenous steroid hormones and metabolites was successfully achieved within a 5 min run time using an UPSFC–MS/MS method (Fig. 2).. The novelty of

The thermodynamic parameters necessary to calculate the entropy production on Mars were obtained using the Laboratoire de Meteorologie Dynamique (LMD) General Circulation Model

Detection of compounds separated by CE is often performed with UV or fluorescence detectors. Although high sensitivities can be obtained, a significant drawback of these