Acquisition of multiple mode shear wave propagation in transversely isotropic medium using dualprobe setup

N/A
N/A
Protected

Academic year: 2021

Share "Acquisition of multiple mode shear wave propagation in transversely isotropic medium using dualprobe setup"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

http://www.diva-portal.org

Postprint

This is the accepted version of a paper presented at Medicinteknikdagarna.

Citation for the original published paper:

Bassan, G., Larsson, D., Nordenfur, T., Bjällmark, A., Larsson, M. (2015)

Acquisition of multiple mode shear wave propagation in transversely isotropic medium using dualprobe setup.

In:

N.B. When citing this work, cite the original published paper.

Permanent link to this version:

(2)

Acquisition of multiple mode shear wave propagation in transversely isotropic medium using dual probe setup

Gioia Bassan1, David Larsson1, Tim Nordenfur1, Anna Bjällmark1, Matilda Larsson1

1Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology,Alfred Nobels Allé 10,

14152 Huddinge, Sweden.

1. Background

Shear Wave Elastography (SWE) is a novel ultrasound-based technique for estimating regional mechanical properties of soft tissue. By measuring the propagation velocity of acoustically initiated shear waves, the tissue elasticity can be derived by assessing the regional speed of the propagating shear waves. However, in commercial systems, the wave propagation analysis have so far been limited to assumptions of infinite and isotropic medium, with such neglecting the complex wave behaviour in non-isotropic biological tissue. In recent years, research studies on SWE analysis in non-infinite and non-isotropic tissue have been performed, however so far with most work focusing on either theoretical analysis of SWE propagation [2] or feasibility trials in pre-defined tissue structures [3]. The aim of this study has therefore been to evaluate the general ability of using SWE to experimentally retrieve multiple transversely isotropic (TI) elasticity measures in a generic transversely isotropic phantom.

2. Method

A TI phantom was made of a water solution with 7%wt of Polyvinyl Alcohol (PVA) and 3%wt of graphite. The phantom underwent two freeze-thaw (FT) cycles, after which it was stretched to 160% of its initial length (Fig. 1(a)) for three additional FT cycles. Stretching induces transverse isotropy [1]. Mechanical axial tests were performed to characterize the elastic moduli in perpendicular and longitudinal direction, respectively. SWE was performed using a programmable ultrasound system (V1, Verasonics Inc, Redmond, WA, USA) with two 128-element linear transducers (L7-4, Philips Healthcare, Andover, MA, USA) in a dual-probe setup (Fig. 1(b)). In each of the two shear wave modes present in TI media, pure-transverse (PT) and quasi-pure-transverse (QT) [2], the shear wave group velocity was measured along 7 directions and deriving the others 5 from symmetry properties. The propagation speeds were compared to theoretical results [2].

3. Results

Fig. 1(c) shows the measured shear wave speeds in PT (red crosses) and QT (blue circles) modes, as well as theoretical propagation speeds in PT (solid red lines) and QT (dashed blue lines). The empirical and theoretical results show good agreement for both wave modes.

4. Discussion

In the following work, we present a way of assessing multiple wave mode acquisition using SWE and a novel dual-probe setup. Initial phantom tissue results indicate a good agreement between experimental data and theoretical predictions, indicating the ability of using SWE as a measurement tool for more complex analysis of mechanical behaviour even for transversely isotropic tissue.

5. References

[1] Chatelin et al. Phys in Med & Bio, 2014, 59(22), doi: 10.1088/0031-9155/59/22/6923 [2] Palmieri et al. J Biomech, 2013, 46(16), doi: 10.1016/j.jbiomech.2013.09.008

[3] Gennison et al, Ultrasoun in Med & Biol, 38(9), doi: dx.doi.org/10.1016/j.ultrasmedbio.2012.04.013 Figure 1(a): Set-up for the stretching Figure 1(b): Set- up for the Dual Probe

Figure 1(c): PT (red) and QT (blue) theoretical propagation modes compared with the velocity estimated using one (red asterisk) and two (blue circles) probes.

Figure

Figure  1(c):  PT  (red)  and  QT  (blue)  theoretical  propagation  modes  compared  with  the  velocity  estimated using one (red asterisk) and two (blue circles)  probes

References

Related documents

The MIDAS models are estimated using high frequency data sampled at 5, 15 and 30 minute intervals and estimated using both exponential Almon and beta lag distributions with two

The collected data indicates that there is, in fact, already a significant use which further validates what the theory states (Goransson and Fagerholm, 2017). Especially data

The choice of dc-link capacitor is partly based on the study the ripple current that the dc-link capacitor will experience. In order to determine the right size of capacitance,

Förutom i de fall tydliga undantag görs för tillämpning i juridisk person, kan det dock inte anses oproblematiskt att anföra att rättvisande bild eller god redovisningssed

Including model specification using the testing contributions above, the third paper considers forecasting with vector nonlinear time series models and extends the procedures

By performing the potential →density and the density→exchange energy per particle mappings based on two model systems characterizing the physics in the interior 共uniform

The research question is defined to answer what current systems exist, meaning that either a survey or an analysis of source is the most suitable research strategy. Both

Tommie Lundqvist, Historieämnets historia: Recension av Sven Liljas Historia i tiden, Studentlitteraur, Lund 1989, Kronos : historia i skola och samhälle, 1989, Nr.2, s..