Nordsyn
– surveillance co-operation for green products
Packages of products for
space heating
Nordic Council of Ministers
This guide presents the technical documentation that you have to
pro-vide if the market surveillance authorities ask for it. There are however
other information requirements and requirements on web-information
that you always need to fulfil according to the regulations.
Technical documentation for packages of space heater, temperature control and solar device
and packages of combination heater, temperature control and solar device
Demands
How to comply
Content of Technical Documentation to provide to market surveillance authorities
Packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device are covered by energy labelling requirements according to Regulation (EU) No 811/2013.
The requirements apply to packages of space heater, temperature control and solar device and packages of combination heater, tempera- ture control and solar device as described in Article 1 and 2 of the above mentioned Regulation.
The documentation shall be produced before the product is placed on the market.
The technical documentation shall be sufficient to enable assessment of the conformity of the product with the requirements. In this respect it is important that test reports are included in the technical documentation.
Name and address of supplier
General description
List of applied standards
Identification and signature of the person empowered to bind the supplier
Technical parameters
Information based on calculations from other combinations
Company name and complete address.
Description of the model so that it is easily identified (model name and number, size etc.). Applied measurement standards (harmonised standards and/or other standards). Name and signature of the person responsible for the product.
For packages of space heater, temperature control and solar devices: • Seasonal space heating energy efficiencyηƞs in %.
• Technical parameters set out in Regulation Annex V Table 7. • Technical parameters for temperature control (see details below). • Technical parameters for solar devices (see details below).
For packages of combination heater, temperature control and solar device: • Seasonal space heating energy efficiency ƞs and water heating energy
efficiencyηƞwh in %.
• Technical parameters set out in Regulation Annex V Table 8. • Technical parameters for temperature control (see details below). • Technical parameters for solar devices (see details below).
For heat pump space heaters and heat pump combination heaters, where the information relating to a specific model with combined indoor and outdoor units is based on calculation or extrapolation from other combinations, state the details of such calculations or extrapola- tions, including details of the mathematical model for calculations and measurements.
Be aware of the rounding rules.
fa ct s ab ou t t he n ordi c co-op era tio n
THE NORDIC REGION
– leading in green growth
Nordic Council of Ministers Store Strandstræde 18 DK-1255 Copenhagen K Phone +45 33 96 02 00 Fax +45 33 96 02 02 www.norden.org
nordsyn september 2015
COMMISSION DELEGATED REGULATION (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device.
Technical documentation for packages of space heater, temperature control and solar device
and packages of combination heater, temperature control and solar device
Demands
How to comply
Technical parameters for temperature control
Technical parameters for solar devices
Specific precautions
• Class of temperature control.
• Contribution of temperature control to seasonal space heating energy efficiency in %.
• Collector aperture area Asol in m2.
• Collector efficiency ƞcol in %.
• Energy efficiency class of the solar hot water storage tank, determined in accordance with the Regulation Annex II point 3.
• Standing loss S of the solar hot water storage tank in W.
• Storage volume V of the solar hot water storage tank in litres and m3.
• Annual non-solar heat contribution Qnonsol in kWh in terms of primary energy for
electricity and/or in kWh in terms of GCV for fuels, for the load profiles M, L, XL and XXL under average climate conditions.
• Pump power consumption, solpump in W. • Standby power consumption, solstandby in W.
• Annual axillary electricity consumption Qaux in kWh in terms of final energy.
State any specific precautions that should be taken when package of space heater or combination heater, temperature control, and solar device is assembled, installed or maintained.
This guide presents the contents of the Regulations and is addressed to manufacturers, importers and others interested. The guide is not a substitution for the Regulations, and in any case of doubt, the Regulations are applicable. This guide is not legally binding as a binding interpretation can only be made by the EU court.
Be aware of the rounding rules in the measurement standard.