1
0
0

Loading.... (view fulltext now)

Full text

(1)

1

2

3

10.0

12.5 14.6 16.1 30.6

9.2

0.6

0.5

2.545.08

1 2 3

GND VCC OUTPUT

0.4

4.0 5.8

1.4

4.0

5.8 R2.75

R o H S C o n f o r m i t y

INFRARED PRODUCTS

( Infrared Emitting Diode )

REV:C DATE:2009/9/21

2DEVICE NO:IR5040 2LENS COLOR:

colored transparent Ö water clear

2PACKAGE DIMENSIONS:

NOTE:

1.All dimensions are in millimeter.

2.Lead spacing in measured where the lead emerge from the package.

3.prodruded resin under flange is 1.5mm max.

4.specifications are subject to change without notice.

5.Tolerance is 0.3mm unless otherwise noted.

2ABSOLUTE MAXIMUM RATINGS:

TA=25℃

PARAMETER SYMBOL MAX. RATING UNIT

Supply Voltage Vcc 2.7 ~ 5.0 V

Operating Temperature Topr -40 ~ +85 °C

Storage Temperature Tstg -40 ~ +85 °C

Dip Soldering Temperature (4mm from case Bottom 260 °C for 5 seconds)

2ELECTRIC-OPTICAL CHARACTERISTICS:

TA=25℃

PARAMETER SYMBOL TEST CONDITION MIN TYP MAX UNIT

Supply Voltage Vcc DC voltage 2.7 - 5.0 V

Supply Current Icc No signal input 1.5 mA

At the ray axis 12

Reception Distance L

In the range of 45ocone 6 m

B.P.F Center Frequency fo 38 kHz

Peak Wavelength lp 940 nm

Half angle θ 45 deg

High Level Pulse Width TH 400 800 μs

Low Level Pulse Width TL 400 800 μs

High Level Output Voltage VH 10cm over the ray axis 4.5 V

Low Level Output Voltage VL 10cm over the ray axis 0.5 V

HUEY JANN ELECTRONICS INDUSTRY CO., LTD.

References

Related documents

Conversion Factors for Important Physical Units Raman Laser Sources and Stokes Shifts. Conversion Tables for Length, Volume,

The IR-UV ion-dip spectroscopy is applied in the first part of this thesis to record conformer-specific spectra of small, aromatic molecules of biological importance, and is

The images are captured using the T640 thermal camera, feature detection results are presented for different pre- processing methods on one image in the sequence by Figure 19....

Provförlopp/upplysningar/sammanfattning Medlems nr. Söker ut nerför brant skogsparti. Går trångt på slag. Upptag på stor fälthare 8.50 som ses vid två tillfällen på

Noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) is a technique for ultra-sensitive detection of molecular absorption and dispersion. For highest

Businesses must comply with various local rules for their products and services to be legally supplied in each market.. DIVERGING

To order, specify bearing ID, OD and length size number (in millimeters) plus material

Three main types of studies are addressed: the use of near-edge X-ray absorption fine structure spectra NEXAFS to manifest through-bond and through-space interactions; the role