Sevcon Ltd TVTE Gateshead Tyne & Wear England NE11 0QA Tel +44 (0)191 4979000 Fax +44 (0)191 4824223 www.sevcon.com Commercially confidential You are authorised to open and view any electronic copy

we send you of this document within your organisation and to print a single copy.

Otherwise the material may not in whole or in part be copied, stored electronically or communicated to third parties without the prior written agreement of Sevcon Limited.

Application Note

Title Adding PDOs

Filename Adding PDOs.docx

Date of Creation 20/08/2010 11:13:00 by Matthew Karas Last Updated 20/08/2010 16:40:00 by Matthew Karas

Revision 1

Contents

1. Introduction... 2 2. Extras ... 3

(2)

Page 2 of 9

1. Introduction

PDOs are the communications items that are sent or received by the Gen4. You can configure these items using DVT.

Note – the pictures in these documents might not reflect the latest version of DVT.

Note – any changes to PDOs must be done in preoperational mode. This app note assumes that the controller is in preop.

Note – this app note is applicable for DVT and DVT customer.

Footnotes1.

1 Footnote text.

(3)

Page 3 of 9

2. Configuring Default PDOs

• Open the helper by clicking the icon on the DVT tool bar.

• You should see the helper window.

• Click the TPDO/RPDO page in the helper.

(4)

Page 4 of 9

Figure 1 Click the "Setup PMAC Debug TPDO" button to set PMAC pdo default communications

• Click the setup PMAC Debug TPDO button or use the can pull down menu to set up induction motor default pdos.

Figure 2 - Induction motor pdo defaults

• Key recycle the power to the unit.

• Verify that the settings have taken place by clicking the icon on the DVT toolbar.

• In preop the values will display as -100000 but will be real values when the vehicle is operational.

(5)

Page 5 of 9

Figure 3 TPDOs show as -100000.0 in pre-operational mode.

Figure 4 Items will show actual values in operational mode.

(6)

Page 6 of 9

3. Configuring specific TPDOs

• Open the DVT helper and go to the TPDO/RPDO pane.

• Click the “Setup TPDO #” button for one of the five available TPDOs.

• Edit the tpdo to transmit what you’d like o Select an item by left clicking the row

 Click “remove – item” to remove the item from the pdo.

 Click “move item up” to have the item transmit at the top of the pdo.

 Click “move item down” to have the item transmit at the bottom of the pdo.

 Click “read pdo” to undo the changes you’re making and read in the settings on the controller

 Click “write pdo” to confirm your changes and write the settings to the controller – you will not be able to undo this command.

(7)

Page 7 of 9

• To add items to a pdo there must be bits left in the pdo – you may have to remove items from the pdo to put in what you want.

Figure 5 You must have free bits in the pdo to add new items

• Click add item

(8)

Page 8 of 9

Figure 6 Search for the item you want to add to the pdo

• You must search for the item you want to add to the pdo using the search pane that pops up after clicking “add item” – certain items will cause an error when you try to add them. Only certain items can be transmitted on a pdo. Double clicking the item will place it in the pdo.

• Click write pdo to confirm the settings.

(9)

Page 9 of 9

4. Extras

A NOTE indicates important information that helps you make better use of your computer system.

A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

A WARNING indicates the potential for bodily harm and tells you how to avoid the problem.

References

Related documents

In general, I have searched for literature using the online journal list at the Library of Uppsala University, as well as with the use of Libris. Additionally, I have used

The inductance will oppose the cause of the changing magnetic field, namely the increasing current, by inducing a voltage with opposite potential compared with the source

The deviation in radial- and tangential- stator flux linkage between results obtained in COMSOL Multiphysics and FEMM is below 0.001Wb which is seen in Figure 5-1 (b)..

Then you do the induc- tion hypothesis and assume that the statement holds for some arbitrary positive integer p, and if you can show that the statement holds for p + 1 you can by

The second solution is an open- loop speed estimator, based on the machine equations only, used in conjunction with a field oriented control drive with speed and current

IM 1 drive behaviour from motor mode to generator mode (ramp of 500 rpm/s, 100% of the rated load, experimental): (a) reference speed, (b) estimated speed, (c) actual

This errata deals with errors in the dissertation but not with errors in original publications attached to the printed version of the dissertation. Page Description At present

Therefore, when we add this observation on the close relationship of the discussed passages to the well-organised plot structure of A Shrew, including the special