• No results found

Determination of kinetic parameters in Integrated Fixed Film Activated Sludge for Amol’s industrial park wastewater treatment plant

N/A
N/A
Protected

Academic year: 2021

Share "Determination of kinetic parameters in Integrated Fixed Film Activated Sludge for Amol’s industrial park wastewater treatment plant"

Copied!
1
0
0

Loading.... (view fulltext now)

Full text

(1)

Linnaeus ECO-TECH 2016 Kalmar, Sweden, November 21-23, 2016

229

DETERMINATION OF KINETIC PARAMETERS

IN INTEGRATED FIXED FILM ACTIVATED

SLUDGE FOR AMOL’S INDUSTRIAL PARK

WASTEWATER TREATMENT PLANT

Nastaran Azimi

1

Maedeh Sadeghpour Haji

2

Ghasem Najafpur

3

1

Islamic Azad University

2

Islamic Azad University

3

Noshirvani University of Technology

Iran

Abstract

Amol industrial park treatment plant (WWTP) collecting the effluent from a number of industries such as fruit juice and meat processes plant, poultry processing plant, glass industrial unit, paperboard factory, tomato cannery, dairy farm harvest and many more small plants. The wastewater treatment plant was monitored for a period of six months (Winter 2012 and Spring 2013). The aim of the present study was to demonstrate how effectively a well monitored Integrated Fixed Film Activated Sludge (IFAS) system can be operated. The value obtained for the COD removal efficiency range was between 98 to 99 percent. The data obtained were fitted by the kinetic models described in this paper and also the kinetic coefficients such as the endogenous decay coefficient (Kd), the growth rate constant (KS), rate constant (k) and yield coefficient (Y) range were determined between 0.062-0.121 d-1 , 54.7-215.2 mg/l, 2.6-10.3 d-1 and 0.419-0.502 mg/mg, respectively. Results showed that except

Ks other coefficient were in the normal range. There is a direct relationship between the variation of Kd and Ks with effluent substrate concentration. But, the relationship between K and effluent substrate is reversed. Finally, the effect of sludge retention time (SRT) on COD removal and sensitivity analysis was conducted.

Keywords

References

Related documents

Using this updated mass flow rate and new guess of boreholes, the model will again size the heat exchanger, heat pump and the borehole thermal energy storage and check if the

Different views of possible systems layouts, where the energy cell module are drawn, the water circu- lation systems area are shown in blue, the electric systems in orange,

Figure 14 shows phosphorous concentration and pH in a diagram. In order to establish this, other factors have to remain unchanged to make sure there are no other influences that

On the basis of the results received after rejecting the outlayers as well as the re­ action time and technological and non - technological aspects mentioned above,

Paper 2 quantifies the air flow inside a wall built by the air gap method and shows that it is a relation between the power of the heating cable, the increased temperature in the

Målet var en eskalering av dessa intervall men utgångspunkten för arbetet var en objektiv granskning av vilka findings TUIfly nordic har haft under sin operation och med

In response to a call for innovative teaching practices pro- moting students’ twenty-first century skills (e.g., Binkley et al. 2012 ), a STEM seminar for pre-service mathematics

The interpolation method is based on representing the views with channel-coded orientation [3], [4], and optimizing all pose parameters (including position, rotation and scale in