• No results found

Modelling of time-varying HRV using locally stationary processes

N/A
N/A
Protected

Academic year: 2021

Share "Modelling of time-varying HRV using locally stationary processes"

Copied!
1
0
0

Loading.... (view fulltext now)

Full text

(1)

44

081 - Modelling of Time-varying HRV using Locally Stationary Processes

Rachele Anderson*

1

, Peter Jönsson

2

and Maria Sandsten

1

1 Mathematical Statistics, Centre for Mathematical Sciences, Lund University, Lund, Sweden

2School of Education and Environment, Centre for Psychology, Kristianstad University, Kristianstad, Sweden

* rachele@maths.lth.se

I. I

NTRODUCTION &

A

IM

Estimates of heart rate variability (HRV), and particularly parameters related to high frequency HRV (HF-HRV), are in-creasingly used as a proxy of cardiac parasympathetic nervous system regulation. Reduced HF-HRV is related to attention deficits, depression, various anxiety disorders, long-term work related stress or burnout, and cardiovascular diseases [1,2]. In this work, a stochastic model, known as Locally Stationary

Processes, [3], is applied to HRV data sequences from 47 test

participants. The model parameters are estimated with a novel inference method and regression using a number of available covariates is used to investigate their correlation with the stochastic model parameters.

II. M

ETHODS

A. Test Description

The test participants (TP) were told not to ingest food, caf-feine, or tobacco during the 2 h before the experiment or alco-hol the day before lab visit. Patients using medicines or suffe-ring form any disease known to affect the cardiovascular system were not included. ECG and respiration were recorded at 1 kHz. ECG was assessed using disposable electrodes and respiration using a strain gauge over the chest. 5 min of data were recorded when the TP was breathing in accordance with a time-varying metronome beginning at 0.12 Hz and ending at 0.35 Hz.

B. Data Preprocessing

The raw data sequences (respiratory data and HR data) were downsampled to 4 Hz, i.e. in total 1200 samples for each se-quence. After adjusting to zero-mean, both respiratory and HR data were filtered with a band-pass FIR-filter of length 256 of 3 dB-bandwidth 0.1-0.5 Hz. The first and last data samples were corrupted from the transient of the filter and as data for the further analysis, the middle 960 samples (4 minutes) were

used.

C.Stochastic model and regression

The stochastic model considered, known as Locally

Station-ary Processes (LSP), is based on the modulation in time of a

stationary covariance function. A novel inference methodology based on the separability properties possessed by the model co-variance is used to estimate the model parameters for every par-ticipant in the study. A generalised linear model with the LSP parameters as response is fitted to investigate their correlation with a number of covariates, including age, gender, height, weight, BMI, and stress level.

C

OMPLIANCE WITH

E

THICAL

R

EQUIREMENTS

Data collection took place at the Department of Laboratory Medicine, Division of Occupational and Environmental Medi-cine, Lund University. The study was approved by the central ethical review board at Lund (Dnr 2013/754) and was con-ducted in correspondence with the Helsinki declaration. All participants signed an informed consent that clearly stated that participation was voluntary and could be discontinued at any time.

C

ONFLICT OF INTEREST

The authors declare that they have no conflict of interest.

R

EFERENCES

1. Gates KM, Gatzke-Kopp LM, Sandsten M, Blandon AY (2015) Es-timating time-varying RSA to examine psychophysiological link-age of marital dyads. Psychophysiology. doi:10.1111/psyp12428. 2. Dolatabadi AD, Khadem SEZ, Asl BM (2017) Automated diagnosis

of coronary artery disease (CAD) patients using optimized SVM.

Computer Methods and Programs in Biomedicine, 138, 117–126.

3. Silverman R (1957) .Locally stationary random processes. IRE

References

Related documents

46 Konkreta exempel skulle kunna vara främjandeinsatser för affärsänglar/affärsängelnätverk, skapa arenor där aktörer från utbuds- och efterfrågesidan kan mötas eller

In this thesis a mathematical approach is applied to analyse sales statistics using the multiple regression model in order to construct a model that predicts the value of an

Meanwhile, a goal programming based method is illustrated to solve the problem of critical path identifi cation, considering four considerable criteria including time, cost,

For time heterogeneous data having error components regression structure it is demonstrated that under customary normality assumptions there is no estimation method based on

We will in this talk use some of the methods described in [1] and [3] to compare the effect of the geometries and the distributions of the inclusions on the effective conductivity of

This feature of a frequency- dependent time window is also central when the wavelet transform is used to estimate a time-varying spectrum.. 3 Non-parametric

The wire frame model description of the test structure is created where the measurement points (MP) are defined as nodes (asterisk) and the geometry as elements, refer Figure

The above simple variants of the congression technique were described in detail by numerical examples in order to make the reader familiar with tbose approaches