Blood coagulation on electron beam melted implant surfaces, implications for bone growth

N/A
N/A
Protected

Academic year: 2022

Share "Blood coagulation on electron beam melted implant surfaces, implications for bone growth"

Copied!
1
0
0

Loading.... (view fulltext now)

Full text

(1)

RESULTS

Thrhombogenicity is presented visually in Figure 3.

Mean R

a

35.0µm 28.5µm 28.2µm Std R

a

3.24µm 2.14µm 1.7µm

Figure 3: Shows the percentage of platelets bonded to the surfaces versus mean values and standard deviation of

average surface roughness (R

a

).

CONCLUSION

The surface properties of the EBM manufactured

specimens are affected by the process parameters. The results in Figure 3 corresponds well with previous results that rougher surfaces promotes bone ingrowth[1]. The

measured thrombogenicity dependence of surface properties (Ra) clearly indicates that the EBM process parameter settings could affect the final bone response in a positive manner.

FURTHER WORK

When flat EBM intrinsically rough surfaces are sufficiently investigated a further research on 3D mesh and net

structures (see Figure 5) will be done. Then the lattice size of the mesh will be the object of the research. A net or

mesh structure have less strength but better flexibility than the solid counter parts witch could be more suitable for

replacement of human bone. Experiments will be carried out in vivo as well as in vitro.

Figure 5: Photograph of a 3D mesh structure.

INRTODUCTION

Electron beam melting (EBM) has great potential in manufacture of various implant geometries for bone replacement. The surfaces have an intrinsic roughness originating from melted metal powder grains (see

figure 1). The EBM-machine process parameter

settings affect the surface properties to some extent.

According to Frosch et. al. rougher surfaces promote bone ingrowth[1]. In addition the thrombogenic

behaviour of implants is believed to be important for osseointegration. [3]

This work is an investigation of how the EBM process parameters affect the surface’s

thrombogenic properties and relate it to bone ingrowth.

Figure 1: Scanning electron microscope image of a flat EBM intrinsically rough surface.

METHODS

The manufacture of the test specimens was carried out with Arcam A2 EBM

®

equipment. Material was a

cobalt-chromium based alloy. Process parameters were changed in the software EBM control[2] and three groups of eight coin like specimens were

manufactured with different parameter setting. The specimens were then tested with fresh whole blood from two individuals in a modified version of the

blood chamber model[3] (see Figure 2). Surface roughness was also characterised using a stylus profiler Dektak

®

6M.

Figure 2:

Specimen and

chambers used in the Blood

Chamber model.

Blood Coagulation on Electron Beam Melted Implant Surfaces, Implications for Bone Ingrowth

Rebecca P. Klingvall

1

, Jaan Hong

2

and Slavko Dejanovic

1

24

th

European Conference on Biomaterials – September 4

th

– 9

th

, Dublin 2011

REFERENSES 1.Frosch, K.H. and K.M. Stürmer, Metallic biomaterials in skeletal repair. European Journal of Trauma, 2006. 32(2): p. 149-159. 2.Arcam, A.; Available from: www.arcam.com. 3.Thor, A., et al., The role of whole blood in thrombin generation in contact with various titanium surfaces.

Biomaterials, 2007. 28(6): p. 966-974

1

Department of Engineering and Sustainable Development, Mid Sweden University, Sweden rebecca.klingvall@miun.se

2

Department of Immunology, Genetics and Pathology, Uppsala University, Rudbeck Laboratory, Uppsala Sweden

References

Related documents

1594, 2017 Center for Medical Image Science and Visualization (CMIV) Division of Radiological Sciences. Department of Medical and Health Sciences

appositional bone growth on hydroxyapatite coated implants (29, 115), a greater bone to implant contact (26, 51), implant ingrowth (115) or interface shear strength (37, 56)

Karin Wermelin Clinical and Experimental Medicine Department of Medical and Health Sciences. Linköping University, Sweden

kontinuerligt slingrande mönster (på engelska snaking pattern) över ytan mellan konturerlinjerna. Pulverbaserade AM-metoder har främst två problem i dagsläget, dessa är den grova

EBM-system består av en elektronpistol med volframfilament, vakuumkammare (~ 10 −4 Torr), en uppvärmd byggplattform och pulverfördelningsmekanismer som är pulverbehållare och

The hardened zone induced by the gaussian beam distribution has been shown to change in terms of its size and shape, in response to changing the magnitude of its overall input

We have shown that high levels of serum serotonin are associated with increased risk of all fractures, nonvertebral osteoporotic fractures and hip fractures in ambulatory

High Serum Serotonin Predicts Increased Risk for Hip Fracture and Nonvertebral Osteoporotic Fractures: The MrOS Sweden Study.. Kristjansdottir H.L., Lewerin C., Lerner U.H.,