Design of a bench-scale ammonia-SrCl2 thermochemical storage system using numerical modelling

N/A
N/A
Protected

Academic year: 2022

Share "Design of a bench-scale ammonia-SrCl2 thermochemical storage system using numerical modelling"

Copied!
10
0
0

Loading.... (view fulltext now)

Full text

(1)

1

EUROTHERM112-XX-YYY

Design of a bench-scale ammonia-SrCl

2

thermochemical storage system using numerical modelling

Saman Nimali Gunasekara1, Michail Laios1, Anastasiia Karabanova2, Viktoria Martin1 and Didier Blanchard2

1Department of Energy Technology, KTH Royal Institute of Technology, Brinellvägen 68, SE-100 44, Stockholm, Sweden, Phone: 46 73652 3339, 46 76563 5044, 46 8790 7484, e-mail:

saman.gunasekara@energy.kth.se; laios@kth.se; viktoria.martin@energy.kth.se

2Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, P.O. Box 49, DK-4000 Roskilde, Denmark. Phone: 45 4677 5899, 45 7183 6790, e-mail: dibl@dtu.dk;

anaka@dtu.dk

Abstract

This work presents the numerical modelling of a bench-scale thermochemical storage (TCS) system based on the reversible absorption-desorption of ammonia in strontium chloride. The modelling is performed using the ASPEN software and was validated against experimental data from literature on a different TCS system configuration but using the same reaction pair. The modelled TCS system in this work comprises two identical reactors, alternatively operating as absorber or desorber with a storage capacity of 0.5 kWh. The system is designed to store and release heat under 8 bar of NH3 pressure, with the two identical reactors respectively undergoing desorption at 82 °C and absorption at 79 °C. Together with the two reactors, a liquid ammonia storage tank is used as a buffer (10 bar at 25 oC). The desorption half-cycle of the system is made of the desorber (82 °C, 8 bar), a compressor (8-10 bar), a cooler (108-25 °C), a pump (to pump liquid ammonia) and the liquid ammonia storage (25 °C, 10 bar). The absorption half-cycle starts form the liquid ammonia storage tank and goes via an expansion valve (10-8 bar) and then a heater (18-25 °C) towards the absorber (79 °C, 8 bar). In the model, the desorption and absorption are respectively driven by an external heater and cooler, which represent a waste heat source and a heat sink respectively. The efficiency of the TCS system was found to be of 67 % and 61 % for the absorption and desorption half-cycles, respectively. A sensitivity analysis was also conducted to identify optimum operating conditions. In conclusion, this study presents an ammonia-SrCl2

TCS bench-scale system that allows simultaneous heat storage and retrieval, as the basis for the practical construction of the system. This is expected to provide inspiration and operational analysis to accommodate the design of similar TCS systems for storing surplus industrial heat.

Keywords: thermochemical storage (TCS), NH3-SrCl2 system, absorption, desorption, numerical modelling, Aspen

1 Introduction

Thermal energy storage (TES) is an essential part in today’s energy system management to combat climate change, allowing improved efficiencies, renewable energy sources integration and mitigation of fossil fuels-based CO2 emissions. TES brings attractive advantages through peak shaving and load shifting [1], [2], and by balancing the time and locational mismatch between thermal energy supply and demand [3], [4]. Thermochemical heat/cold storage (TCS) is one compact TES alternative with the potential to provide storage densities up to 5 times larger than the state of the art phase change materials (PCMs), or up to 25 times the one of sensible TES

(2)

2

[5]. TCS involve physical endo/exothermic processes like adsorption, or chemical processes through reversible chemical reactions (via absorption/desorption).

One of the most-investigated adsorption-based TCS systems today uses water as adsorbate on zeolite as adsorbent [6]-[9]. The majority of TCS systems involving chemical reactions also primarily employ water as absorbate and salts as absorbents, forming salt hydrates from compounds such as MgCl2 [8], [10]-[12]; CaCl2 [10]-[15]; MgSO4 [10], [12], [15]; MgCl2 [15], [16]; SrBr2 [8], [11], [12]; Na2S [8], [17]; NaOH [8], [18], [19]; LiBr [13], and Al2(SO4)3 [10], or salt hydroxides such as Ca(OH)2 (from CaO)[20]-[22]. These water-based systems can be designed as opened or closed configurations since water is not hazardous.

Chemical reactions-based TCS systems using other absorbates than water require closed system operation since the employed absorbates (fluid) should not be directly released to the atmosphere.

Among such TCS designs, numerous systems involve the reaction pair NH3 (absorbate) and a metal halide (absorbent) such as [23], SrCl2 [24]-[30], MnCl2 [31]-[34], CaCl2 [34], [35], BaCl2

[32], [36], MgCl2 [37], and NH4Cl2 [33]. These systems offer higher energy storage densities than the water-based systems and more flexibility in the system operating pressures. Some of these NH3-metal halide TCS systems are also designed with two respective salts for low-temperature (LT) and high-temperature (HT) cycles, using e.g. BaCl2 and MnCl2 [32], NH4Cl2 and MnCl2

[33], CalCl2 and MnCl2 [34], [38], and two different ammines of CaCl2 [35]. A majority of these NH3-Metal halide TCS systems utilize the gas-solid reaction (e.g. [25]-[34], [37], [38]) while some also consider the reaction between solid-liquid (e.g. [28]). Many of these designed TCS systems consist of a single reactor that operates in batch-mode, alternatively storing and releasing heat with NH3 desorption and absorption, respectively (e.g. [25], [28], [29], [31], [37]). Whereas, some other NH3-metal halide TCS designs comprise two separate reactors for simultaneous absorption and desorption, either for the same reaction pair [26], [27], or for different reaction pairs for the LT and HT cycles respectively, containing two different salts [32]-[34], [38], or two different ammines [35]. Most of these systems maintain the solid absorbent within the reactor, but a few transport the solid absorbent, e.g. in powder form between the absorber and desorber [26].

This work is part of a project within a Nordic collaboration: Neutrons for Heat storage (NHS) [39]. The NHS project leaders at DTU, Denmark, have already constructed a bench-scale single reactor TCS system for the NH3-SrCl2 reaction pair [29] and use neutron imaging, radiography and tomography, to improve the reactor design and therefore the efficiency of the whole TCS.

The project partners at KTH, Sweden, aim to design a bench-scale TCS system to simultaneously store and release low-temperature heat at 40-80 ℃ using the same NH3-SrCl2 reaction system. A bench-scale system was chosen as a sufficient representation of the behavior of a real-life application system (unlike at laboratory-scale), while still being economical in construction. The experimental analysis of this bench-scale TCS system is then expected to yield important design implications for the scaling-up of the system to e.g. pilot-scale, and provide valuable experimental data on e.g. the reaction kinetics. Inspired by the findings on the TCS system at DTU as well as from literature, the current work aims to develop the preliminary design of this TCS system using ASPEN Plus numerical modelling [40] to accommodate simultaneous heat storage and retrieval around 80 ℃ using two identical reactors with a storage capacity of 0.5 kWh each.

2 Methodology

Here, the theoretical background, the conceptual design of the chosen TCS system, and important aspects and assumptions regarding modelling the system using Aspen Plus [40] are presented.

2.1 Operating principle

(3)

3

The reaction pair NH3-SrCl2 undergoes two main reaction steps as displayed in Eqn. 1 and Eqn.

2, to achieve the complete transformation from pure SrCl2 to its octaammine (SrCl2·8NH3), as expressed in Eqn. 3. Here, ΔH denotes the respective reaction enthalpy for each case, where absorption is an exothermic reaction and desorption is endothermic. In this work, only the specific reversible chemical reaction between the monoammine (SrCl2·NH3) to octaammine, (Eqn. 2) are considered because it fulfills the desired working temperature/pressure conditions.

NH3(g) + SrCl2(s) ⇆ SrCl2·NH3(s) + ΔH Eqn. 1 7 NH3(g) + SrCl2·NH3(s) ⇆ SrCl2·8NH3(s) + ΔH Eqn. 2 8 NH3(g) + SrCl2(s) ⇆ SrCl2·8NH3(s) + ΔH Eqn. 3 The enthalpy and entropy of the reaction between the monoammine and octaammine are respectively 41.4 kJ/molNH3and 230 J/(mol·K) [41], i.e., involving seven ammonia molecules per molecule of salt. Whereas, the enthalpy and entropy values for the last ammine are 48.1 kJ/molNH3and ~230 J/(mol·K) [41]. Thus, the reaction of the last ammine is the most energetic step and requires, for its desorption, either a too high temperature (> 150 ℃ at ~8 bar) or a very low pressure (> 670 mbar, at 80 ℃) [29]. In-addition, during this reaction step, the salt undergoes the largest volume change per ammine (125%), a change detrimental for the system [29].

Therefore, this TCS system design excludes the conversion of the last ammine, and is thus restricted to the reaction between SrCl2·NH3 and SrCl2·8NH3 (Eqn. 2).

For a heat storage capacity of 0.5 kWh, the calculation of the amounts of NH3, SrCl2·NH3 and SrCl2·8NH3 needed for the stoichiometric reaction is explained in Eqn. 4-Eqn. 9 (where, the molar masses of NH3, SrCl2·NH3 andSrCl2·8NH3 are17.03 g/mol, 175.55 g/mol, and 294.77 g/mol respectively).

0.5 𝑘𝑘𝑘𝑘ℎ = 0.5𝑘𝑘𝑘𝑘/𝑠𝑠 × 3600𝑠𝑠 = 1800 𝑘𝑘𝑘𝑘 Eqn. 4 For 1 mole of NH3, the required moles of SrCl2·NH3 = 1/7 molSrCl2·NH3 Eqn. 5

SrCl2·NH3 toSrCl2·8NH3 conversion enthalpy = 41.4 kJ/molNH3 Eqn. 6

To store 0.5 kWh, the amount of NH3 needed =41.4 kJ/𝑚𝑚𝑚𝑚𝑚𝑚1800 kJNH3= 43.48 molNH3 Eqn. 7 Thus, the amount of SrCl2·NH3 needed = 6.21 molSrCl2·NH3 = 1090.38 gSrCl2·NH3 Eqn. 8

The amount of SrCl2·8NH3 needed 6.21 molSrCl2·8NH3 = 1830.86 gSrCl2·8NH3 Eqn. 9

The progression of the reaction (Eqn. 1-Eqn. 3) depends on the pressure and temperature. This reaction system’s equilibrium pressure depends on temperature, and can be expressed using the Van’t Hoff’s equation, as in Eqn. 10 [29], [41]. Here, 𝑝𝑝𝑒𝑒𝑒𝑒 is the equilibrium pressure (Pa), 𝑝𝑝0 is the reference pressure equal to 1 Pa, ∆𝐻𝐻 and ∆𝑆𝑆 are respectively the reaction enthalpy (J/mol) and entropy (J/(mol·K)), T is the reaction temperature (K) and R is the ideal gas constant (8.314 J/(mol·K)).

𝑝𝑝𝑒𝑒𝑒𝑒 = 𝑝𝑝0∙ 𝑒𝑒𝑒𝑒𝑝𝑝 �−∆𝐻𝐻 𝑅𝑅𝑅𝑅 +

∆𝑆𝑆 𝑅𝑅 �

Eqn. 10

The specific operating temperatures and pressures are chosen for both absorption and desorption around 80 ℃ (the upper margin of the range 40-80 ℃). This was done by referring to the equilibrium pressure-temperature curve of the NH3-SrCl2 system, for the conversion between SrCl2·NH3 andSrCl2·8NH3. This is plotted (based on the Van’t Hoff equation, in Eqn. 10) together with the phase diagram of NH3 in Figure 1. As Figure 1 indicates, the equilibrium pressure for this TCS system at 80 ℃ is 7.73 bar. That is, to accommodate absorption, the system should be maintained above 7.73 bar at 80 ℃, whereas for desorption it should be maintained below 7.73

(4)

4

bar. Therefore, this condition is chosen as the marginal condition between the two reactions, for this TCS system design work.

Figure 1. NH3 phase diagram (based on data from [42]) and SrCl2·NH3-SrCl2·8NH3 equilibrium pressure (Peq)- temperature (Teq) plot (based on the Van’t Hoff equation [29], [41])

2.2 Conceptual design and numerical modelling with Aspen Plus

Based on the equilibrium condition of SrCl2·NH3 andSrCl2·8NH3 system at 80 ℃ and 7.73 bar, for operational simplicity, the reaction pressure was chosen to be at 8 bar. For this 8 bar reaction pressure, it was chosen to maintain absorption at 79 ℃ (Peq=7.42 bar < 8 bar) and desorption at 82 ℃ (Peq=8.37 bar > 8 bar) in agreement with Figure 1. The storage of NH3 is more cost-effective in liquid state. Therefore, to be able to store NH3 in liquid-state at room temperature (at or below 25 ℃), it was decided to maintain NH3 at 10 bar, according to the NH3 phase diagram in Figure 1. To accommodate simultaneous absorption and desorption in these conditions, the conceptual design of the TCS system is established as in Figure 2. As Figure 2 shows, the TCS system contains two identical reactors for alternating absorption desorption reaction (as indicated by the dashed lines).

Desorber

Absorber Compressor

Cooler Pump

NH3(l) Storage

Tank Evaporator

(Expansion valve) Heater

(Absorber) (Desorber) 8 bar, 82 ℃

8 bar, 79 ℃

10 bar, 25 ℃ 8 bar, T??

(<25 ℃)

8 bar, 25 ℃ 10 bar,

25 ℃ 10 bar,

25 ℃ 10 bar, T??

(> 25 ℃) 8 bar,

~82 ℃ External

Heater

External Cooler TH,in >

82 ℃ TH,out

??

TC,in , 25 ℃ 25 ℃ < TC,out

< 79 ℃

Figure 2. The conceptual design of the TCS system NH3-SrCl2·NH3 for simultaneous absorption/desorption between SrCl2·NH3-SrCl2·8NH3 (T is the temperature, the subscripts H and C denote respectively the external heater and

external cooler, with ‘in’ representing the inlet, and ‘out’ the outlet)

For a given reaction half-cycle, NH3 gas that is desorbed at 8 bar is compressed to 10 bar (the NH3 storage pressure) using a compressor. The temperatures of some of the streams (e.g. the outlets of the desorber, compressor, evaporator, external heater and external cooler, as well as the inlet of the external heater) are unknown and expected to be found through the numerical modelling. As the compression will heat-up NH3, it is then cooled to 25 ℃, by the cooler, into liquid-state at 10 bar, and is then pumped to the NH3 storage tank. This stored NH3 is then used in absorption, by expanding to 8 bar (with eventual cooling), heating back to 25 ℃ (by the heater) thus converting it into gas, and then sending into the absorber at 8 bar and 79 ℃. The absorber and desorber will be maintained at these desired temperatures using an electrically operated external cooling and heating source respectively.

(5)

5

This conceptual design of the system is then modelled using ASPEN Plus (V9) [40]. The simulation identify all the inlet and outlet conditions and the optimal operating conditions. The model was validated against experimental data from literature on a different TCS system configuration but using the same reaction pair [25]. A sensitivity analysis was also performed on the current ASPEN-based system to analyze its optimal operating conditions.

For modelling the TCS system in ASPEN, the flow rates of materials are required. These rates (0.01087 molNH3/s, and 0.00155 mol/s respectively of SrCl2·NH3 andSrCl2·8NH3) are obtained by dividing the respective amounts of NH3, SrCl2·NH3 and SrCl2·8NH3 in the system (43.48 molNH3, and 6.21 mol respectively of SrCl2·NH3 and SrCl2·8NH3), by the reaction time:

4000 s. This time was chosen based on the semi-empirical absorption and desorption times, 4000 s and 3000 s reported by Nagamalleswara Rao et al. [27] (derived using experimental data from Huang et al. [24]) for the same reaction pair and similar amount of salt (1 kg). Accordingly, to ensure complete transformation even during the slower reaction (i.e., desorption), 4000 s was chosen here for both reactions. In ASPEN, an RGibbs reactor was selected [40] as the most suitable type for this reaction process. Inherently, ASPEN software does not allow a reactor to contain reactants or products inside the reactor in batch-mode, but instead, requires a continuous in- and out-flow of all reactants and products. Due to this limitation, unlike the real reactor that maintains the salts inside the reactor, in the model, the reactants are sent in while the products are sent out from the reactors, continuously. That is, in the ASPEN model, using the derived flow rates, NH3 and monoammine are sent into the absorber while octaammine is sent out, and vice- versa in the desorber. Consequently, as the outlet stream of the desorber contains a mixture of NH3 and SrCl2·NH3, NH3 gas is separated from the solid SrCl2·NH3 in a separator, because it is only NH3 that should be circulated towards the rest of the system. This feature appears only in the model, as for the real system this separator is unnecessary (because there, the solid salt always remains inside the reactor). These streams are however still within the system boundary, and thus can still correctly represent the real system’s operation in ASPEN.

In this work, heat losses and pressure losses in the system were neglected, while NH3 leaving the cooler and the evaporator (expansion valve) is respectively assumed to be saturated and superheated. The external heater and cooler were chosen to be the model 1166D from VWR (with heating and cooling capacities, and total volume being 2.2 kW, 0.1-0.2 kW (for -10 to 20 ℃) and 6 l) [43], with the heat transfer fluid (HTF): Therminol 66 [44].

3 Results and discussion

The final design of the NH3-SrCl2 TCS system for the simultaneous absorption and desorption (between SrCl2·NH3 and SrCl2·8NH3) in ASPEN is shown in Figure 3, and the corresponding real system is shown in Figure 4. As explained, the real system in Figure 4 excludes the separator as it retains the solid salt always within the reactors. The calculator blocks in the ASPEN model, in Figure 3, mathematically match the heat duties of the external heating/cooling sources with those needed to maintain the respective temperatures in the reactors. The results yielded the unknown temperatures of the system’s various streams, now combined into Table 1, detailing the operating conditions of all the streams in the system (the data from simulations in bold). The inlet temperature of the HTF from the external heater was chosen as 88 ℃, assuming a 6 ℃ temperature gap between the reactor and the HTF is sufficient to encourage the desired heat transfer. The modelled TCS system can therefore operate at around 80 ℃ as desired, storing heat at 82 ℃ in the desorber, and releasing the stored heat at 79 ℃ in the absorber, each at 8 bar. After all, maintaining a temperature at an exact set point is practically difficult, and therefore these operating temperatures will be achieved in a range, in the practical system.

(6)

6

Figure 3. The Aspen model of the NH3-SrCl2 TCS system for the simultaneous absorption and desorption. (COMPRESS: compressor, SEPARAT: Separator, STORAGE: NH3(l) storage, EXPANVAL: Expansion valve, HEX1: external heater, and HEX2: external cooler)

Table 1. The detailed operating conditions of the designed TCS system in the Aspen model (in bold are the conditions found through Aspen simulations)

Component Desorber Compressor Cooler Pump NH3(l)

storage Expansion

valve Heater Absorber External

heater External cooler

Inlet T (℃), P (bar) 82, 8 82, 8 108, 10 25, 10 25, 10 25, 8 18, 8 79, 8 88, 1 25, 1

Outlet T (℃), P (bar) 82, 8 108, 10 25, 10 25, 10 25, 10 18, 8 25, 8 79, 8 85, 1 64, 1

ABSORBER Q=-0

COMPRESS W=0

PUMPW=0

STORAGEQ=-0

SEPARAT Q=-0

HEATERQ=0

DESORBER Q=0

EXPANVAL COOLER

Q=-0

HEX1 Q=-0

CALCULATORB2

HEX2 Q=0

DESIGN-SPECB4

DESIGN-SPECB1 CALCULATORB3

79 NH3CL2 8

82 CL-28NH3 8 82

8 7NH3- 108

10 7NH3--

25 7AMMONIA 10

25 10 AMMON-7

18 8 AMMO

25 8 AMMON

79 8 CL28NH3

82 CL2NHE 8 25

S7 10

82 8 NH3-1AMM

88 2 S1 Q S3

85 2 S2

25 2 S4 64 2 S5

Q S6

Temperature (C) Pressure (bar) Q Duty (Gcal/hr)

W Power(kW)

(7)

7

Liquid NH3 storageExpansion Valve

External Cooler Heater

25 °CHTF 64 °CHTF

SrCl2·NH3

NH3 (g)

25 °C, 8 bar

79 °C, 8 bar NH3 (l)

25 °C, 10 bar NH3 (l)

25 °C, 10 bar

NH3 (l)

25 °C, 10 bar NH3 (g)

18 °C, 8 bar

Alternating Valve NH3 (g)

25 °C, 8 bar 82 °C, 8 bar

Absorber Desorber

Compressor External

Heater Cooler

Pump

88 °CHTF 85 °CHTF NH3 (g)

82 °C, 8 bar NH3 (g)

108 °C, 10 bar NH3 (l)

25 °C, 10 bar NH3 (l)

25 °C,

10 bar Alternating

Valve

SrCl2·8NH3

Figure 4. The real NH3-SrCl2 TCS system of the Aspen model with simultaneous absorption and desorption (HTF:

Heat transfer fluid)

A numerical model needs to be verified with experimental data, whenever possible, to improve the validity of the model as a whole, as well as its results. For this reason, the ASPEN (numerical) model of the TCS system in this project (referred to as the ‘desired TCS system’) is verified here by using experimental data from literature [25]. This is done by adapting the desired TCS system’s ASPEN model to reproduce the solar-driven TCS system from Erhard et al. [25] along with its components and operating conditions. This solar-driven TCS system employed 2.2 kg of SrCl2

with 1.67 kg of NH3 in a single reactor [25] (as in Figure 5). The Aspen model adapted to the system of Erhard et al. [25] is here referred to as the ‘verification model’, and is shown in Figure 6. In this model, the ice storage of Erhard et al. [25] was neglected for simplicity, as a reasonable assumption, as it does not directly affect the NH3 sorption cycle. In the system of Erhard et al.

[25], the same reactor undergoes desorption during the day (when sun shines) and absorption at night. In the verification model here, both these reactions are simultaneously represented by the two respective reactors in the desired TCS system model. Similarly, a common heat exchanger used by Erhard et al. [25] is separated-out into the cooler and heater in Figure 5, which already exist in the desired TCS system. The TCS system of Erhard et al. [25] (and hence the verification model here), excludes the compressor because it is designed for ambient temperatures around 40

℃ at which NH3 pressure reaches 16 bar (and is liquid), and by cooling this NH3 the 3 bar reaction pressure is obtained. Furthermore, their system excludes a pump, as the liquid flow is operated under-gravity [25]. These aspects are maintained in the verification model here. The evaporative power of the system is reported to be 20 W [25], and the verification model simulation here also yielded the same evaporative power of 20 W. This result therefore verifies the validity of the ASPEN model of the desired TCS system in this work.

Cooler

Reactor

Solar Heat Collector Solar Heat

Collector

Liquid NH3 Storage Evaporator

NH3 (l)

40 °C,

16 bar Ice

storage Desorption: 103 °C, 16 bar/

Absorption: 59 °C, 3 bar

NH3 (l)

40 °C, 16 bar

NH3(l), -10 °C, 3 bar NH3 (g)

103 °C, 16 bar

NH3 (l)

40 °C, 16 bar

NH3 (g)

59 °C, 3 bar Heater NH3 (g)

-10 °C, 3 bar

Figure 5. The real TCS system of Erhard et al. [25] used in the verification model construction

(8)

8

Figure 6. The verification model in Aspen (by adapting this work’s TCS system to that by Erhard et al. [25])

The ASPEN model yields the desired storage capacity of 0.5 kWh on each reactor, during absorption and desorption. The energy efficiency of the absorption and desorption half-cycles are respectively 67 % and 61 % (considering the total energy use in each half-cycle, for storing 0.5 kWh energy).

The sensitivity analysis on the HTF regarding the inlet temperatures of the external heater and cooler and the corresponding volumetric flow rates are summarized in Figure 7. As Figure 7 indicates, the volumetric flow rates of the HTF in the external heater and cooler to maintain the desired respective inlet temperatures of 88 ℃ and 25 ℃, the HTF flow rates should be 5.3 l/min and 0.4 l/min respectively. These flow rates thus are reasonable for the chosen thermal bath’s capacity, and hence further verify the feasibility of the designed TCS system’s practical operation.

Figure 7. The influence of the heat transfer fluid temperature on its required flow rate (in the external cooler and heater)

In-contrast to the most comparable TCS systems in literature, this TCS system design has the novelties of: being modelled in ASPEN (therefore with more flexibility in operating conditions analysis) for this specific layout and operating conditions; the use of an NH3 buffer (allowing safer operation) unlike the system proposed by Nagamalleswara Rao et al. [27]; and allows simultaneous heat storage and release unlike in the TCS system at DTU [29].

ABSORP

STORAGE

SEPARAT

HEATER

DESORB COOLER1

VALVE

59 NH3CL2 3

103 CL-28NH3 16 103

16 7NH3-

40 16 AMMON-7

-9 3 AMMO

59 3 AMMON

59 3 CL28NH3 103

8 CL2NH3

40 S7 16

103 16 NH3-1AMM

Temperature (C) Pressure (bar)

(9)

9

As a next step in the project, the model will be used to investigate further the system’s behavior and the requirements of additional components (particularly compressors, heaters and coolers) for the entire operating temperature range of 80-40 ℃. It will be used to assess the possible modifications to increase the TCS efficiency such as for example replacing the compressor by additional cooling steps, which would considerably reduce the electricity consumption. Overall, the bench-scale TCS system model in ASPEN will be thoroughly scrutinized and analyzed to find the optimal configuration to be built at KTH. The bench-scale TCS system, once constructed, is expected to yield practical implications in terms of its energy consumption, energy efficiency, energy losses, potential improvements, and experience for scaling it up. Such an ‘optimized’

practical system can be scaled-up to store waste heat from industries, data center servers, and like, that can then be used to complement district heating. The simultaneous operation at the bench- scale was sought here more for the concept demonstration and trouble-shooting of the complete absorption and desorption within the same cycle. Whereas, at an application, the additional reactor could serve as a back-up. Or else, this system can also be split, by constructing the absorption half-cycle at the heat consumer and the desorption half-cycle at the heat source, where each reactor and the ammonia storage are designed as removable and portable units that can be transported between the consumer and heat source.

4 Conclusions

This work successfully numerically modelled a TCS system in ASPEN using the system NH3- SrCl2, for the simultaneous heat storage (desorption) and release (absorption) at 82 ℃ and 79 ℃ (and 8 bar pressure) respectively with a heat storage capacity of 0.5 kWh. The system has an energy efficiency of 67% during absorption, and 61% during desorption. This TCS system model was verified against experimental results published for another rather similar TCS system using the same reaction pair, and a sensitivity analysis suggesting the optimum thermal bath flow rates to maintain the expected reaction temperatures. As the next steps, this system will be analyzed to find out if the use of the compressor can be replaced with more cooling steps for a more economical system, as well as for the entire operating temperature range 40-80 ℃.

Acknowledgements

The authors sincerely acknowledge Nordforsk for funding the NHS project, the NHs project partners for their constructive inputs, Dr. Stefano Soprani for the details on the TCS system at DTU, Mr. Shoma Fuji for the valuable suggestions on TCS systems design, as well as Dr. Duleeka Gunarathna and Dr. Mahrokh Samavati for their great assistance to learn Aspen software.

References

[1] F. Kuznik, A. Lopez, J. Pablo, D. Baillis and K. Johannes, "Design of a PCM to air heat exchanger using dimensionless analysis: Application to electricity peak shaving in buildings," Energy and Buildings, vol. 106, pp. 65-73, 2015.

[2] R. Barzin, J. J. J. Chen, B. R. Young and M. M. Farid, "Peak load shifting with energy storage and price-based control system," Energy, vol. 92, pp. 505-514, 2015.

[3] T. Nomura, N. Okinaka and T. Akiyama, "Technology of latent heat storage for high temperature application: a review," ISIJ international, vol. 50, no. 9, pp. 1229-1239, 2010.

[4] J. N. Chiu, J. F. Castro Flores, V. Martin and B. Lacarrière, "Industrial surplus heat transportation for use in district heating," Energy, vol. 110, pp. 139-147, 2016.

[5] I. Sarbu and C. Sebarchievici, "A Comprehensive Review of Thermal Energy Storage," Sustainability, Vols. 10, 191, pp. 1-32, 2018.

[6] R. Cuypers, N. Maraz, J. Eversdijk, C. Finck, E. Henquet, H. Oversloot, H. van ’t Spijker and A. de Geus, "Development of a seasonal thermochemical storage system," Energy Procedia, vol. 30, pp. 207-214, 2012.

[7] A. Krönauer, E. Lävemann, S. Brückner and A. Hauer, "Mobile Sorption Heat Storage in Industrial Waste Heat Recovery," Energy Procedia, vol. 73, pp.

272-280, 2015.

[8] L. Scapino, H. A. Zondag, J. Van Bael, J. Diriken and C. C. M. Rindt, "Energy density and storage capacity cost comparison of conceptual solid and liquid sorption seasonal heat storage systems for low-temperature space heating," Renewable and Sustainable Energy Reviews, vol. 76, pp. 1314-1331, 2017.

[9] S. Fujii, Y. Kanematsu, Y. Kikuchi, T. Nakagaki, J. N. Chiu and V. Martin, "Techno economic analysis of thermochemical energy storage and transport system utilizing “Zeolite Boiler”: case study in Sweden," Energy Procedia, vol. 149, pp. 102-111, 2018.

(10)

10

[10] H. Zondag, B. Kikkert, S. Smeding, R. de Boer and M. Bakker, "Prototype thermochemical heat storage with open reactor system," Applied Energy, vol. 109, pp. 360-365, 2013.

[11] K. E. N'Tsoukpoe, T. Schmidt, H. U. Rammelberg, B. A. Watts and W. K. Ruck, "A systematic multi-step screening of numerous salt hydrates for low temperature thermochemical energy storage," Applied Energy, vol. 124, pp. 1-16, 2014.

[12] A. Fopah Lele, K. E. N'Tsoukpoe, T. Osterland, F. Kuznik and W. K. Ruck, "Thermal conductivity measurement of thermochemical storage materials,"

Applied Thermal Engineering, vol. 89, pp. 916-926, 2015.

[13] Y. I. Aristov, G. Restuccia, G. Cacciola and V. N. Parmon, "A family of new working materials for solid sorption air conditioning systems," Applied Thermal Engineering, vol. 22, pp. 191-204, 2002.

[14] K. Korhammer, M.-M. Druske, A. Fopah-Lele, H. U. Rammelberg, N. Wegscheider, O. Opel, T. Osterland and W. Ruck, "Sorption and thermal characterization of composite materials based on chlorides for thermal energy storage," Applied Energy, vol. 162, pp. 1462-1472, 2016.

[15] H. U. Rammelberg, T. Osterland, B. Priehs, O. Opel and W. K. Ruck, "Thermochemical heat storage materials – Performance of mixed salt hydrates," Solar Energy, vol. 136, pp. 571-589, 2016.

[16] A. Fopah Lele, F. Kuznik, H. U. Rammelberg, T. Schmidt and W. K. Ruck, "Thermal decomposition kinetic of salt hydrates for heat storage systems," Applied Energy, vol. 154 , pp. 447-458, 2015.

[17] A.-J. de Jong, L. van Vliet, C. Hoegaerts, M. Roelands and R. Cuypers, "Thermochemical heat storage – from reaction storage density to system storage density," Energy Procedia, vol. 91, pp. 128-137, 2016.

[18] B. Fumey, R. Weber, P. Gantenbein, X. Daguenet-Frick, T. Williamson and V. Dorer, "Closed sorption heat storage based on aqueous sodium hydroxide,"

Energy Procedia, vol. 48, pp. 337-346, 2014.

[19] X. Daguenet-Frick, P. Gantenbein, J. Müller, B. Fumey and R. Weber, "Seasonal thermochemical energy storage: Comparison of the experimental results with the modelling of the falling film tube bundle heat and mass exchanger unit," Renewable Energy, vol. 110, pp. 162-173, 2017.

[20] K. G. Sakellariou, N. I. Tsongidis, G. Karagiannakis and A. G. Konstandopoulos, "Shortlisting of Composite CaO-Based Structured Bodies Suitable for Thermochemical Heat Storage with the CaO/Ca(OH)2 Reaction Scheme," Energy Fuels, vol. 31, pp. 6548-6559, 2017.

[21] J. Yan and C. Y. Zhao, "Thermodynamic and kinetic study of the dehydration process of CaO/Ca(OH)2 thermochemical heat storage system with Li doping,"

Chemical Engineering Science, vol. 138, pp. 86-92, 2015.

[22] M. Schmidt, A. Gutierrez and M. Linder, "Thermochemical energy storage with CaO/Ca(OH)2 – Experimental investigation of the thermal capability at low vapor pressures in a lab scale reactor," Applied Energy, vol. 188, pp. 672-681, 2017.

[23] T. X. Li, R. Z. Wang, T. Yan and T. F. Ishugah, "Integrated energy storage and energy upgrade, combined cooling and heating supply, and waste heat recovery with solid–gas thermochemical sorption heat transformer," International Journal of Heat and Mass Transfer, vol. 76, p. 237–246, 2014.

[24] H.-J. Huang, G.-B. Wu, J. Yang, Y.-C. Dai, W.-K. Yuan and H.-B. Lu, "Modeling of gas–solid chemisorption in chemical heat pumps," Separation and Purification Technology, vol. 34, p. 191–200, 2004.

[25] A. Erhard, K. Spindler and E. Hahne, "Test and simulation of a solar powered solid sorption cooling machine," International Journal of Refrigeration, vol.

21, no. 2, pp. 133-141, 1998.

[26] M. Al-Zareer, I. Dincer and M. A. Rosen, "Heat Transfer and Thermodynamic Analyses of a Novel Solid–Gas Thermochemical Strontium Chloride–Ammonia Thermal Energy Storage System," Journal of Heat Transfer, vol. 140, no. February, pp. 022802-1 - 022802-17, 2018.

[27] K. NagaMalleswara Rao, M. Ram Gopal and S. Bhattacharyya, "Analysis of a SrCl2–NH3 solid sorption refrigeration system," International Journal of Low- Carbon Technologies, vol. 10, p. 365–373, 2015.

[28] K. Kuwata, S. Masuda, N. Kobayashi, T. Fuse and T. Okamura, "Thermochemical Heat Storage Performance in the Gas/Liquid-Solid Reactions of SrCl2 with NH3," Natural Resources, vol. 7, pp. 655-665, 2016.

[29] S. Soprani, "MODELING – TES system based on SrCl2 - NH3," Technical University of Denmark (DTU), Lyngby, 2017.

[30] T. X. Li, R. Z. Wang and T. Yan, "Solid-gas thermochemical sorption thermal battery for solar cooling and heating energy storage and heat transformer,"

Energy, vol. 84, pp. 745-758, 2015.

[31] T. X. Li, J. X. Xu, T. Yan and R. Z. Wang, "Development of sorption thermal battery for low-grade waste heat recovery and combined cold and heat energy storage," Energy, vol. 107, pp. 347-359, 2016.

[32] T. X. Li, R. Z. Wang, J. K. Kiplagat and H. Chen, "Experimental study and comparison of thermochemical resorption refrigeration cycle and adsorption refrigeration cycle," Chemical Engineering Science, vol. 65, p. 4222–4230, 2010.

[33] H. S. Bao, R. Z. Wang, R. G. Oliveira and T. X. Li, "Resorption system for cold storage and long-distance refrigeration," Applied Energy, vol. 93, p. 479–

487, 2012.

[34] L. Jiang, L. W. Wang, C. Z. Liu and R. Z. Wang, "Experimental study on a resorption system for power and refrigeration cogeneration," Energy 97, vol. 97, pp. 182-190, 2016.

[35] T. Li, R. Wang, J. K. Kiplagat and Y. Kang, "Performance analysis of an integrated energy storage and energy upgrade thermochemical solide gas sorption system for seasonal storage of solar thermal energy," Energy, vol. 50, pp. 454-467, 2013.

[36] T. X. Li, R. Z. Wang, L. W. Wang and J. K. Kiplagat, "Study on the heat transfer and sorption characteristics of a consolidated composite sorbent for solar- powered thermochemical cooling systems," Solar Energy, vol. 83, pp. 1742-1755, 2009.

[37] S. A. H. Mofidi and K. S. Udell, "Study of Heat and Mass Transfer in MgCl2/NH3 Thermochemical Batteries," Journal of Energy Resources Technology, vol. 139, no. May, pp. 032005-1 - 032005-10, 2017.

[38] F. Q. Zhu, L. Jiang, L. W. Wang and R. Z. Wang, "Experimental investigation on a MnCl2-CaCl2-NH3 resorption system for heat and refrigeration cogeneration," Applied Energy, vol. 181, p. 29–37, 2016.

[39] Nordforsk, "Neutrons For Heat Storage," Nordforsk, [Online]. Available: https://www.nordforsk.org/en/programmes-and-projects/projects/neutrons-for-heat- storage. [Accessed 14 February 2019].

[40] aspentech, "aspentech: Technology That Loves Complexity," aspentech, [Online]. Available: https://www.aspentech.com/en/products/engineering/aspen- plus. [Accessed 14 February 2019].

[41] S. Lysgaard, A. L. Ammitzbøll, R. E. Johnsen, P. Norby, U. J. Quaade and T. Vegge, "Resolving the stability and structure of strontium chloride amines from equilibrium pressures, XRD and DFT," International Journal of Hydrogen Energy, vol. 37, pp. 18927-18936, 2012.

[42] e. John R. Rumble, "Fluid Properties - Vapor Pressure of Fluids at Low Temperatures," in CRC Handbook of Chemistry and Physics, 99 ed., vol. 99th Print Edition (Internet Version 2018), Boca Raton, FL, CRC Press/Taylor & Francis.

[43] VWR, "VWR Circulators and Chillers," 2018. [Online]. Available: http://edge.rit.edu/edge/P13621/public/VWR_Circulators_Chillers_Manual.pdf.

[Accessed 08 August 2018].

[44] Eastman Chemical Company, "Therminol- Heat Transfer Fluids by Eastman," Eastman Chemical Company, 2018. [Online]. Available:

https://www.therminol.com/sites/therminol-prd.us-east-1.elasticbeanstalk.com/files/documents/TF-08_Therminol_66.pdf. [Accessed 21 February 2019].

References

Related documents

our suggested critical pluralistic approach is to recognise the difference of nonhuman species by how animal bodies and agency can enable humans to act in political and ethical

Det blir synligt i denna avhandling när jag studerar situationer typiska enligt ovan, och undersöker hur de nationella kursplanerna formas till olika lokala kursplaner i relation

Överlag tycktes respondenterna i de stora kommunerna vara mer insatta i både Kommuninvests verksamhet och deras sätt att hantera risker, men gemensamt för alla kommuner var att

Neuroticism har ett samband med upplevelsen av studiekrav är baserat på resultat från Nilsson.. Det bekräftade resultatet från föreliggande studie kan bidra till en ökad

The temperature curve at the production point showed as similar behaviour to that of the base case scenario but with a delayed and lower peak of temperature, again as one might

After reviewing the related literature, the parameters to assess the system’s performance have been identified, including the amount of released/stored heat (kJ), the energy