Distal Radioulnar Joint: Arthroplasty and Strength assessments AKADEMISK AVHANDLING

N/A
N/A
Protected

Academic year: 2021

Share "Distal Radioulnar Joint: Arthroplasty and Strength assessments AKADEMISK AVHANDLING"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Avhandlingen baseras på följande delarbeten: I Axelsson P, Sollerman C, Karrholm J.

Ulnar Head Replacement: 21 Cases; Mean Follow-Up, 7.5 Years. J Hand Surg Am. 2015;40(9):1731-8.

II Axelsson P, Sollerman C.

Constrained implant arthroplasty as a secondary procedure at the distal radioulnar joint: early outcomes.

J Hand Surg Am. 2013;38(6):1111-8. III Axelsson P, Karrholm J.

New methods to assess forearm torque and lifting strength: reliability and validity. (In press, J Hand Surg Am.)

IV Axelsson P, Fredrikson P, Nilsson A, Andersson JK, Karrholm J. Forearm torque and lifting strength: normative data. (In press, J Hand Surg, Am.)

V Axelsson P, Sollerman C, Karrholm J.

Validity and responsiveness of forearm strength measurements in the evaluation of distal radioulnar joint implant arthroplasty.

(In manuscript)

Distal Radioulnar Joint: Arthroplasty and Strength assessments

AKADEMISK AVHANDLING

Som för avläggande av medicine doktorsexamen vid Sahlgrenska akademin, Göteborgs Universitet kommer att offentligen försvaras i Hörsal Arvid Carlsson, Academicum,

Medicinaregatan 3, Göteborg, fredagen den 2 mars, 2018, kl. 13.00 av

PETER AXELSSON

Leg läkare Fakultetsopponent:

Docent ELISABET HAGERT

Institutionen för klinisk forskning och utbildning, Karolinska Institutet, Stockholm

(2)

Abstract

The growing interest in distal radioulnar (DRUJ) disorders underlines the need for further improved evaluations of treatment outcome. Load-bearing and optimising torque are import-ant features of the DRUJ, but they are rarely measured when assessing DRUJ interventions. To make these measurements easily accessible in clinical situations, we developed two meth-ods for quantifying lifting strength and forearm torque. In this thesis, we report the outcomes after surgery with two types of DRUJ implant arthroplasty and the result of our evaluation of the new strength measurement methods. In Study I, we reviewed 21 patients treated with the Herbert ulnar head prosthesis and, in Study II, we included nine patients treated with the Scheker total DRUJ prosthesis after previously failed DRUJ surgery. For both types of arthroplasty, the patient-reported outcome was satisfactory, scores for pain were low and there were no signs of radiographic loosening. There was one re-operation (Herbert prosthesis), but no other major complications.

In Study III, we assessed the reliability and valid-ity of our methods in quantifying lifting strength and forearm torque. Intraclass correlation co-efficient calculations showed that the inter- and intrarater reliability was excellent and the new methods were also valid when the Baltimore Test Equipment was used as a reference.

In Study IV, we measured 499 healthy volunteers to obtain normal values for our new test meth-ods. Normative data were defined and we were able to compute predictive equations based on gender, age and height.

In Study V, we evaluated the responsiveness and validity of the new strength measurement meth-ods in 18 patients treated with DRUJ implant arthroplasty. We found that forearm torque was more sensitive to change than grip strength. Forearm torque also had a stronger correlation to the other outcome variables.

In conclusion, it was confirmed that the Herbert and Scheker implants are efficient and safe, in the mid-term perspective, in a selected group of patients. Our methods for measuring strength for lifting and forearm rotation were reliable and valid and normative values were defined. Forearm torque outperformed grip strength in the evaluation of DRUJ implant arthroplasty.

Keywords: Distal radioulnar joint arthroplasty, Forearm torque and lifting strength measurements, Normative data, Reliability, Validity,

Responsiveness

ISBN: 978-91-629-0390-9 (PRINT) ISBN: 978-91-629-0391-6 (PDF) http://hdl.handle.net/2077/54529

Distal Radioulnar Joint: Arthroplasty and Strength assessments

PETER AXELSSON

References

Related documents

Material and methods: In Study I, hip joint movements were measured with two different dynamic motion analysis systems, an optical tracking system and roentgen

In this seed project, we propose a new data-driven technique that utilizes piezoceramic transducers together with one-dimensional convolutional neural networks (1D CNNs) for

• The aim of the proposed seed project: is to develop a better method for strength grading of timber by making use of piezoelectric transducers and 1D CNNs..?. The

In a third study of our methods (study V), we compared the sensitivity to change and correlation to other outcome variables, when used to evaluate DRUJ implant arthroplasty.

In order to present standardised solutions for future comparison, five joints with different plate

For this analysis, joint with a stiff adhesive (ESP110), a joint with soft adhesive (DP490) and a bi-adhesive joint (combination of ESP110 and DP490) with α = 0.5 are used to

Following TWA with the new implant design in a cadaveric model, there were no statistically significant changes compared to a native wrist regarding flexion, extension,

crosslinking of the polymer is known to negatively affect its fracture toughness, increasing the wear induced by fatigue related delamination wear.. Previously published results