• No results found

Radiological Measurements in Total Hip Arthroplasty

N/A
N/A
Protected

Academic year: 2021

Share "Radiological Measurements in Total Hip Arthroplasty"

Copied!
2
0
0

Loading.... (view fulltext now)

Full text

(1)

Kirurgisk och perioperativ vetenskap

Radiological Measurements in Total

Hip Arthroplasty

Bariq Al-Amiry

Akademisk avhandling

som med vederbörligt tillstånd av Rektor vid Umeå universitet för

avläggande av filosofie doktorsexamen framläggs till offentligt

försvar i Lionsalen, by 7, målpunkt Y22, 2 tr, Umeå

universitetssjukhus

fredag den 12 oktober, kl. 09:00.

Avhandlingen kommer att försvaras på svenska.

(2)

Organization

Document type

Date of publication

Umeå University Doctoral thesis 12-10- 2018

Surgical and perioperative sciences

Author

Bariq Al-Amiry

Title

Radiological Measurements in Total Hip Arthroplasty

Abstract

Every year, about 20000 patients in Sweden undergo total hip arthroplasty (THA), a successful, safe and cost-effective procedure to regain mobility and restore hip joint function in patients suffering from severe hip joint disease or trauma. The radiographic preoperative planning and postoperative evaluation of these parameters require good validity and reliability. This thesis included 4 prospective cohort studies on the radiological measurements in THA.

Study I: Included 90 patients with primary unilateral OA treated with THA. Global femoral offset

(FO) using a standard method compared to a new method (the Sundsvall method), leg length discrepancy (LLD), acetabular cup inclination and anteversion were measured on postoperative radiographs. The interobserver reliability and intraobserver reproducibility were tested using three independent observers. Study II: Included 172 patients with unilateral primary OA treated with THA. LLD and global FO were measured on postoperative radiographs. Patients with lengthening of the operated leg ≥ 10mm (n=41) and patients with reduction of global FO > 5mm (n=58) were further studied to investigate the amount of lengthening and global FO reduction that took place in the stem and in the cup compared with the contralateral side to investigate whether the leg lengthening and FO reduction were related to the stem or cup. Study III: Evaluated the function with (WOMAC) index and QoL with EQ-5D. At 1-year after THA, the same scores and also hip abductor muscle strength were measured postoperatively. We investigated whether the preoperative radiological osteoarthritis (OA) grade and symptom duration influenced the 1-year outcome parameters. Study IV: Included 213 patients. Body mass index (BMI) was documented preoperatively. We evaluated the effect of BMI and other factors on postoperative radiological FO restoration, LLD, acetabular cup anteversion and cup inclination.

The main conclusions were: 1.The radiographic measurement methods of LLD, global FO, cup

inclination and anteversion as well as the Sundsvall method have the required validity and reliability to be used in clinical practice. 2.Lengthening of the operated leg is mainly caused by improper femoral stem positioning while global FO reduction results from improper positioning of both acetabular and femoral components. 3.The preoperative radiological OA grade and symptom duration had no influence on the outcome of THA. 4.Increased BMI showed a negative effect on restoration of post-THA leg length but not on restoration of FO or positioning of the acetabular cup.

Keywords : Total hip arthroplasty; leg length discrepancy; femoral offset; WOMAC; EQ-5D;

quality of life; radiographic measurements; duration; acetabular cup; inclination; anteversion; BMI.

Language ISBN ISSN Number of pages

References

Related documents

Data were collected through questionnaires from patients (ES & QPC-IP) (Hansson & Björkman, 2005; Schröder, Wilde Larsson, Ahlström & Lundqvist, 2010) and staff

Correlations between the PLM test and clinical ratings with the Unified Parkinson’s Disease Rating Scale motor section (UPDRS III) were investigated in 73 patients with

However, the vertical axis principle often simplifies the turbines. In theory that could lead to better economy. The advantages most commonly mentioned are 1) Generator can be placed

This thesis focuses on the optimization of decellularization strategies for blood vessels such as porcine vena cava, to determine the optimal decellularization protocol (Paper I)

To evaluate the interobserver reliability and intraobserver reproducibility of the radiological measurements of postoperative global FO, leg length discrepancy (LLD) and

A similar result as in the case study could have been achieved when redesigning the product even without the suggested DFMA method and since no reference DFMA method

The new expression must then be expanded to form the formal imprint, which means converting it back to a single series of the chosen basis functions, in our case Chebyshev

For the result in Figure 4.8 to Figure 4.11 the effective width method and the reduced stress method is calculated based on the assumption that the second order effects of