EN
RFID GLB
Installation of RFID reader (EN)
380180-2
EN EN
TABLE OF CONTENTS
Installation of RFID reader 5
Disassembling the Wallbox 6
Installing the RFID reader 7
Connect RFID reader 8
Installing the Wallbox 9
Using RFID reader 10
Activating RFID reader 12
Deactivating RFID reader 12
Activating RFID tags 14
Deleting RFID tags 14
4 5 EN EN
An RFID reader can be added alongside the GLB Wallbox, to be installed at a set location. It is connected to the wallbox's printed circuit board header labelled ‘RFID’ using the accompanying cable. The RFID reader can read RFID tags complying with Mifare 1K, 4K and Mifare Ultralight specifications. Once the RFID reader has been installed,
‘Request RFID when connecting’ is displayed on the Wi-Fi wallbox's website under
‘Settings’.
The RFID reader can be installed in an individual wallbox which has Wi-Fi connectivity. It can also be installed in boxes with or without Wi-Fi where the boxes are connected into a group, and at least one of them has Wi-Fi connectivity.
INSTALLATION OF RFID READER
The power supply to the wallbox must always be turned off when the RFID reader is installed.
EN
EN Disassembling the Wallbox Installing the RFID reader
Montageanvisning för installatör / Steg-för-Steg installation
Steg-för-Steg Installation
(figur 4)
1. Kontrollera att matande kabel är strömlös.
2. Lossa borrmall från emballage. (se Lådans innehåll sida 14) 3. Fäst borrmall på vägg där laddaren skall monteras upp.
Lämplig höjd (se Tekniska data sida X) 4. Borra/markera enl. anvisning på borrmall.
5. Lås upp frontluckan på laddaren med den medföljande nyckeln och dra därefter frontluckan nedåt.
6. Frontluckan har ett inbyggt stoppläge. För att komma förbi detta läge, ta tag i frontens underkant och lyft försiktigt utåt samtidigt som du drar nedåt.
Montageanvisning för installatör / Steg-för-Steg installation
(figur 5)
7. Lossa de 7 skruvarna och lyft försiktigt bort locket från bottenlådan.
dip-switch
(figure 1)
8 9 EN
EN Connect RFID Installing the Wallbox
FUSE 2AT
Fuse/RCCB FB Contactor FB Contactor control Line (L)
Neutral (N)
Protective earth (PE)
1 2 3 4 5 6
DataLink E-Meter
Ext. charge control open=on, close=off
*) - see info below
SW2
SW1
Remote control
A - B +
A - B +
Max charging Factory default current (A) 16A
Factory default
SW3
Montageanvisning för installatör / Steg-för-Steg installation
Serienr/SSIDpasswordendast wifiversion
30mA
N L1L2 L3
PE
RCD
INC. TERMINAL
PE NL de nedre pilarna visar anslutningsalternativet 1-fas
Serienr/SSID, password (endast wifi-version) Vid inkommande 1-fas matning
(16A,240V eller 32A,240V) på en 3-fas GLB, skall inkommande fas läggas på plint L1.
8. Skruva upp bottenlådan på vägg med 3st lämpliga skruvar för underlaget. Se röda pilar i figur 6
9. Dra in kabel genom kabelgenomföringen.
10. Koppla in kabel på plintar. Plintar är anpassad för 1,5mm² - 6mm² kabel. Upp till 10mm² i 32A Laddbox.
11. Behöver laddströmmen reduceras? Se avsnitt: Reducering av laddström.
Montageanvisning för installatör / Steg-för-Steg installation
Serienr/SSIDpasswordendast wifiversion
språketikett är placeras på sidan 7 x T20
Sätt försiktigt locket på plats rakt framifrån, var noga med att insats på höger sida hamnar rätt i spår och att det ser rätt ut. Om laddaren har wifi, kontrollera
Kontrollera att Personskyddsbrytare/Jordfelsbrytare är i tillslaget läge.
Montageanvisning för installatör / Steg-för-Steg installation
(figur 8)
15. Montera åter frontluckan genom att trä på den underifrån.
16. Lås frontluckan med nyckel.
Montageanvisning för installatör / Steg-för-Steg installation
(figur 9)
17. Anslut spänning och kontrollera att indikationslampan visar fast grönt sken.
18. Om inte, se avsnitt: Felsökning 19. Vid fast grönt sken är laddaren klar att användas.
Connect RFID reader
The RFID reader is connected to the wallbox's mainboard header labelled ‘RFID’ using the accompanying cable.
Installing the Wallbox
Install the cover and front cover as shown in the section entitled Assembly instructions for installers, under Step by step installation, in GLB main manual.
(figure 2)
Connection to RFID reader
J1
Ext.charge control open=on, close=off
*) - see info below GLB mainboard
EN EN Using RFID
85
(figure 3)
12 13 EN
EN Activating/Deactivating RFID Activating/Deactivating RFID
(figure 5)
Activating RFID reader
To activate the RFID reader, check the box labelled ‘Request RFID when connecting’ and click ‘Save’. Note the checkbox is only visible when a RFID reader is installed.
Deactivating RFID reader
To deactivate the RFID reader, un-check the box labelled ‘Request RFID when connecting’
and click ‘Save’.
GLB mode ON=Master: OFF=Slave SW1
(figure 4)
Activate RFID reader on individual GLB Wallbox
To activate RFID reader on a GLB Walbox that is stand alone (not connected with other GLB Wallboxes), it is important to make the charger a master wallbox.
To verify that the master wallbox is defined as master, ensure the SW1 switch (DIP 5) is set to ‘ON’.
Note: It is only possible to have one Master GLB in a system when connecting GLB Wallboxes with the datalink bus.
EN
EN Activating/deleting RFID Activating/deleting RFID tags
Activating RFID tags
When RFID is activated, you can choose to ‘Add a new tag’. You can now manually register the tag number in the ‘RFID Number’ field, and then click ‘Save’. Alternatively, you can read the tag number by selecting ‘Read tag from wallbox’. To read an RFID tag, hold it towards the RFID reader. The RFID tag number is automatically displayed in the
‘RFID number’ field. Then click ‘Save’. The ‘Reference’ box is a free text field to be used for entering the name of the person using the tag, for example.
When RFID is activated, a registered RFID tag must be held out in order to activate the charger, after the vehicle has been connected. When the RFID reader is attempting to read an RFID tag, a ticking sound is emitted and the green light flashes quickly. The user has 30 seconds to read the RFID tag after having connected the vehicle. A rising three- tone signal is emitted when the tag has been read. If the tag is authorised, the charger will be activated. If the tag is unauthorised (not registered), a longer, block tone will be emitted and a red light indicated.
Deleting RFID tags
To delete a registered RFID tag, click on the minus symbol to the right of the tag number
GARO AB
Box 203, SE–335 25 Gnosjö Phone: +46 (0) 370 33 28 00 Fax +46 (0) 370 33 28 50 info@garo.se