• No results found

RFID GLB Installation of RFID reader (EN)

N/A
N/A
Protected

Academic year: 2022

Share "RFID GLB Installation of RFID reader (EN)"

Copied!
9
0
0

Loading.... (view fulltext now)

Full text

(1)

EN

RFID GLB

Installation of RFID reader (EN)

380180-2

(2)

EN EN

TABLE OF CONTENTS

Installation of RFID reader 5

Disassembling the Wallbox 6

Installing the RFID reader 7

Connect RFID reader 8

Installing the Wallbox 9

Using RFID reader 10

Activating RFID reader 12

Deactivating RFID reader 12

Activating RFID tags 14

Deleting RFID tags 14

(3)

4 5 EN EN

An RFID reader can be added alongside the GLB Wallbox, to be installed at a set location. It is connected to the wallbox's printed circuit board header labelled ‘RFID’ using the accompanying cable. The RFID reader can read RFID tags complying with Mifare 1K, 4K and Mifare Ultralight specifications. Once the RFID reader has been installed,

‘Request RFID when connecting’ is displayed on the Wi-Fi wallbox's website under

‘Settings’.

The RFID reader can be installed in an individual wallbox which has Wi-Fi connectivity. It can also be installed in boxes with or without Wi-Fi where the boxes are connected into a group, and at least one of them has Wi-Fi connectivity.

INSTALLATION OF RFID READER

The power supply to the wallbox must always be turned off when the RFID reader is installed.

(4)

EN

EN Disassembling the Wallbox Installing the RFID reader

Montageanvisning för installatör / Steg-för-Steg installation

Steg-för-Steg Installation

(figur 4)

1. Kontrollera att matande kabel är strömlös.

2. Lossa borrmall från emballage. (se Lådans innehåll sida 14) 3. Fäst borrmall på vägg där laddaren skall monteras upp.

Lämplig höjd (se Tekniska data sida X) 4. Borra/markera enl. anvisning på borrmall.

5. Lås upp frontluckan på laddaren med den medföljande nyckeln och dra därefter frontluckan nedåt.

6. Frontluckan har ett inbyggt stoppläge. För att komma förbi detta läge, ta tag i frontens underkant och lyft försiktigt utåt samtidigt som du drar nedåt.

Montageanvisning för installatör / Steg-för-Steg installation

(figur 5)

7. Lossa de 7 skruvarna och lyft försiktigt bort locket från bottenlådan.

dip-switch

(figure 1)

(5)

8 9 EN

EN Connect RFID Installing the Wallbox

FUSE 2AT

Fuse/RCCB FB Contactor FB Contactor control Line (L)

Neutral (N)

Protective earth (PE)

1 2 3 4 5 6

DataLink E-Meter

Ext. charge control open=on, close=off

*) - see info below

SW2

SW1

Remote control

A - B +

A - B +

Max charging Factory default current (A) 16A

Factory default

SW3

Montageanvisning för installatör / Steg-för-Steg installation

Serienr/SSIDpasswordendast wifiversion

30mA

N L1L2 L3

PE

RCD

INC. TERMINAL

PE NL de nedre pilarna visar anslutningsalternativet 1-fas

Serienr/SSID, password (endast wifi-version) Vid inkommande 1-fas matning

(16A,240V eller 32A,240V) på en 3-fas GLB, skall inkommande fas läggas på plint L1.

8. Skruva upp bottenlådan på vägg med 3st lämpliga skruvar för underlaget. Se röda pilar i figur 6

9. Dra in kabel genom kabelgenomföringen.

10. Koppla in kabel på plintar. Plintar är anpassad för 1,5mm² - 6mm² kabel. Upp till 10mm² i 32A Laddbox.

11. Behöver laddströmmen reduceras? Se avsnitt: Reducering av laddström.

Montageanvisning för installatör / Steg-för-Steg installation

Serienr/SSIDpasswordendast wifiversion

språketikett är placeras på sidan 7 x T20

Sätt försiktigt locket på plats rakt framifrån, var noga med att insats på höger sida hamnar rätt i spår och att det ser rätt ut. Om laddaren har wifi, kontrollera

Kontrollera att Personskyddsbrytare/Jordfelsbrytare är i tillslaget läge.

Montageanvisning för installatör / Steg-för-Steg installation

(figur 8)

15. Montera åter frontluckan genom att trä på den underifrån.

16. Lås frontluckan med nyckel.

Montageanvisning för installatör / Steg-för-Steg installation

(figur 9)

17. Anslut spänning och kontrollera att indikationslampan visar fast grönt sken.

18. Om inte, se avsnitt: Felsökning 19. Vid fast grönt sken är laddaren klar att användas.

Connect RFID reader

The RFID reader is connected to the wallbox's mainboard header labelled ‘RFID’ using the accompanying cable.

Installing the Wallbox

Install the cover and front cover as shown in the section entitled Assembly instructions for installers, under Step by step installation, in GLB main manual.

(figure 2)

Connection to RFID reader

J1

Ext.charge control open=on, close=off

*) - see info below GLB mainboard

(6)

EN EN Using RFID

85

(figure 3)

(7)

12 13 EN

EN Activating/Deactivating RFID Activating/Deactivating RFID

(figure 5)

Activating RFID reader

To activate the RFID reader, check the box labelled ‘Request RFID when connecting’ and click ‘Save’. Note the checkbox is only visible when a RFID reader is installed.

Deactivating RFID reader

To deactivate the RFID reader, un-check the box labelled ‘Request RFID when connecting’

and click ‘Save’.

GLB mode ON=Master: OFF=Slave SW1

(figure 4)

Activate RFID reader on individual GLB Wallbox

To activate RFID reader on a GLB Walbox that is stand alone (not connected with other GLB Wallboxes), it is important to make the charger a master wallbox.

To verify that the master wallbox is defined as master, ensure the SW1 switch (DIP 5) is set to ‘ON’.

Note: It is only possible to have one Master GLB in a system when connecting GLB Wallboxes with the datalink bus.

(8)

EN

EN Activating/deleting RFID Activating/deleting RFID tags

Activating RFID tags

When RFID is activated, you can choose to ‘Add a new tag’. You can now manually register the tag number in the ‘RFID Number’ field, and then click ‘Save’. Alternatively, you can read the tag number by selecting ‘Read tag from wallbox’. To read an RFID tag, hold it towards the RFID reader. The RFID tag number is automatically displayed in the

‘RFID number’ field. Then click ‘Save’. The ‘Reference’ box is a free text field to be used for entering the name of the person using the tag, for example.

When RFID is activated, a registered RFID tag must be held out in order to activate the charger, after the vehicle has been connected. When the RFID reader is attempting to read an RFID tag, a ticking sound is emitted and the green light flashes quickly. The user has 30 seconds to read the RFID tag after having connected the vehicle. A rising three- tone signal is emitted when the tag has been read. If the tag is authorised, the charger will be activated. If the tag is unauthorised (not registered), a longer, block tone will be emitted and a red light indicated.

Deleting RFID tags

To delete a registered RFID tag, click on the minus symbol to the right of the tag number

(9)

GARO AB

Box 203, SE–335 25 Gnosjö Phone: +46 (0) 370 33 28 00 Fax +46 (0) 370 33 28 50 info@garo.se

garo.se

References

Related documents

The aim is to create a prototype that can help us evaluate if a personal mobile RFID reader can help the customer decide which product to buy, by providing additional

Som en indelande del vill vi visa hur teorierna i detta kapitel används för att uppfylla problemformuleringen i denna studie. Som ett stöd för att besvara den första delen i

Efter införande av RFID inom ICA-koncernen kan dessa kort ersättas med Contactless Smart Cards relativt enkelt och man kan på så sätt nå en mycket stor kundkrets som förutom

I dagsläget ställs det höga krav från flygbolagen samt flygplatserna att prestera på bästa sätt för att behålla så många passagerare som möjligt nöjda samtidigt

An optical touch pointer using a fiber-optic based, fluorescence spectroscopy system with continuous and pulsed modulation was developed to detect the 5-ALA

To explore the mechanism behind the perfusion dips, a distal digital nerve block was applied to the third digit of the left hand (dig III sin) in one healthy test subject..

This was achieved by shielding the transponder in aluminum foil and using a RFID blocking card.. Potential damage to the shielding products was also tested, as damage to the

Undersökningen visar att ett intresse för RFID-teknik finns inom dessa företag som intervjufrågor skickats till, trots att tillräcklig information om tekniken inte getts